12.2  

Starting the S0 Wizard (HiPath 500) 
 


Tools | Run S0 Wizard
 
The Wizard provides a guided dialog for entering the most important customer data. The customer data that is needed for an initial startup is collected here and then transferred to the customer database (CDB) of the HiPath 500. Please note, however, that the Wizard only collects the most important customer data that is needed for a fast startup. Detailed entries can be processed later in HiPath 3000 Manager.
During the initial setup, the Wizard deletes the standard key assignment of the first optiPoint. This was originally configured as an Attendant and now has the standard keys of a normal optiPoint 500.  
The Wizard is automatically activated on initial installation.
If the Wizard is not called automatically at the first installation or was canceled for some reason, make sure that you start it manually.  
Make sure that all terminals (system telephones or CMI devices) are connected before starting the Wizard.
Once you have started the Wizard, follow the instructions displayed on the user interface and note the following description:
 1.   The pre-defined data is now HiPath transferred to the HiPath 500. If you receive an error message, check if
   -   the HiPath 500 is operational,
   -   the administration PC is connected to HiPath 500 via an operational serial interface or the LIM.
 2.   The PCPBX-Point-to-multipoint connection type is set by default. The telecommunication provider generally supplies three MSN (CO numbers) for each S0 port. In accordance with the available HiPath 500, one or two ISDN connections can be used for connecting to the public network.
 3.   Under Options, specify if you have a LAN connection and if you want to enter the IP setup at a later stage.

Entering the MAC and IP addresses  
If you did not select the Skip IP setup option:
 4.   Enter the MAC address as described in the note in the dialog.
 5.   Enter the IP address and, if necessary, change the predefined subnet mask.

Configuring access  
 6.   Select how the data should be transferred between HiPath 500 and the PC. After specifying an IP address, also select access via the LAN.
 7.   Then start the transfer of the CDB from the HiPath 500 communication system to your PC.
 8.   Once the Wizard has been completed, additional settings can be implemented in order to optimize the communication system to best meet your needs. You can do this for the communication system settings by using the functions of the System view. For customized settings, you will need to switch to the Station view (see also Chapter 3 "Operation").
 9.   Once you have created the customer data, it is transferred back to the (see Transfer | Communication).
Your communication system is now operational.
The Wizard can also be run more than once. Note that in such cases, the currently loaded CDB is taken into account in the Wizard. In other words, all features which were set up later using HiPath 3000 Manager and which are not handled via the input masks of the Wizard are retained.  

See also  
   -   Section 2.4 "Wizard"
   -   Chapter 3 "Operation"
   -   Section 9.19.1 "Transfer | Communication"