2.3  

System-Specific Capacity Limits for HiPath 3000, HiPath 5000 
 
The maximum capacity limits are calculated based on the following assumptions:
 •   HiPath 3800: two board slots are reserved for trunks.
 •   HiPath 3550, HiPath 3500: Two S0 interfaces on the central board + 1 board slot are reserved for trunks.
 •   HiPath 3350, HiPath 3300: Two S0 interfaces on the central board are reserved for trunks.
 •   Traffic capacity: 0.15 erlangs
Alternative capacity limits may be determined for sales purposes.
Table 10-9 contains the maximum system-specific configurations for UP0/E workpoint clients and the corresponding add-on modules and adapters. Refer to the section "Capacities" in the system description for a more detailed data table.

 Table 2-26   HiPath 3000/5000 - System-Specific Capacity Limits (Maximum Configuration)
 System  
 HiPath 38001  
 HiPath 3550  
 HiPath 3500  
 HiPath 3350  
 HiPath 3300  
 HiPath ComScendo Service  
 Stations/Workpoint Clients  
Total Number of TDM and IP Stations2  
 500  
 963  
 964  
 965  
 966  
 -  
IP stations (system clients)  
 500  
 967  
 967  
 967 8  
 967 9  
 1000  
Total number of TDM stations2  
 384  
 9610  
 7710 11  
 5712  
 4113  
 -  
 TDM Stations  
Analog stations  
 384  
 962  
 4414  
 3615  
 2016  
 -  
UP0/E stations  
 384  
 7217  
 4818  
 2419  
 2420  
 -  
Additional stations via adapter (phone adapter/analog adapter/ISDN adapter)  
 116  
 4810  
 2910  
 2421  
 2421  
 -  
Cordless stations  
 250  
 64/3222 23  
 32  
 16  
 16  
 -  
Base Stations forHiPath Cordless Office  
 64  
 16/7  
 7  
 3  
 3  
 -  
 Lines  
Total Number of Lines  
 250  
 60  
 60  
 16  
 16  
 -  
Total number of analog trunks and network trunks  
 120  
 60  
 60  
 16  
 8  
 -  
Total number of B channels on digital trunks and digital network trunks (S0, S2M)  
 180  
 60  
 60  
 16  
 16  
 -  
CorNet IP network trunks  
 128  
 60  
 60  
 16  
 16  
 250  
HG 1500 boards  
 8  
 3  
 3  
 1 (224)  
 1 (224)  
 -  
Gateway channels to the system  
 128  
 48  
 48  
 16  
 16  
 -  
1System load is greatly dependent on factors such as system configuration and traffic. Static rules on configuration inspection are therefore not suitable. As a guide, configurations that include UCD/ACD, more than one SLC16N, groups with more than 10 stations or OpenScape Office connections should always be inspected using the project planning tool ( https://enterprise-businessarea.siemens-enterprise.com/productinfo/document/9fTFkWdA76U_/HiPath%203000%20V8%20Planungsanleitung%20Performance%20Calculation%20Tool.xls ).
2Only configurations that do not exceed this limit will be supported.
3Up to 96 stations can be TDM stations.
4Up to 61 of the 96 stations can be TDM stations (4xanalog T/R + 1xUP0/E + 7xBS/32xHiPath Cordless Office stations at the central board + 3xSLU8R or 3x8SLAR or 3xSLAD8R).
5Up to 41 of the 96 stations can be TDM stations (4xa/b + 5xUP0/E + 3xBS/16xHiPath Cordless Office stations at the central board + 1x16SLA).
6Up to 33 of the 96 stations can be TDM stations (4xa/b + 5xUP0/E + 3xBS/16xHiPath Cordless Office stations at the central board + 1xSLU8R or 1x8SLAR or 1xSLAD8R).
7These are administrative capacity limits.
8Due to the power consumption of HG 1500, a UPSC-D must be used.
9Due to the power consumption of HG 1500, a UPSC-DR must be used.
10If the total number of UP0/E stations, analog stations and additional stations connected using an adapter is greater than 72, an external power supply unit (Powerbox PB3000 with LUNA2) must be used.
114xa/b + 1xUP0/E + 7xBS/32xHiPath Cordless Office stations at the central board + 5xSLU8R or 5x8SLAR or 5xSLAD8R.
124xa/b + 5xUP0/E + 3xBS/16xHiPath Cordless Office stations at the central board + 2x16SLA.
134xa/b + 5xUP0/E + 3xBS/16xHiPath Cordless Office stations at the central board + 2xSLU8R or 2x8SLAR or 2xSLAD8R.
144xa/b at the central board + 5x8SLAR or 5xSLAD8.
154xa/b at the central board + 2x16SLA.
164xa/b at the central board + 2x8SLAR or 2xSLAD8.
178xUP0/E at the central board + 5xSLU8 + 1xSLMO24.
188xUP0/E at the central board + 5xSLU8R.
198xUP0/E at the central board + 2xSLU8.
208xUP0/E at the central board + 2xSLU8R.
21If the total number of UP0/E stations and additional stations connected using an adapter is greater than 24, UPSC-D/UPSC-DR must be used.
22Due to the 5-V power supply unit, one SLC16N and a maximum of two HG 1500 V3.0 boards can be used.
2364 HiPath Cordless Office stations at the SLC16N or 32 HiPath Cordless Office stations at the central board.
24The system may be configured with two HG 1500 boards if PDM1 is not used.