12.4.5 |
Recording the Status of the HiPath 3000 V.24 Interfaces |
| You can use HiPath 3000/5000 Manager E to view the current status of the V.24 interfaces, in which case the following information is provided. |
| • | Status of the trunks (1 = active trunk, 0 = inactive trunk) The individual trunks are assigned as follows: DTR = HiPath 3000 DSR = Telephone RTS = HiPath 3000 CTS = Telephone |
| This means, for example, that incorrectly connected or damaged cables can be determined (for more information on this, refer to the HiPath 3000/5000 Manager E Help). |
| • | V.24 Monitoring The number of sent/received bytes within a selected time period can be recorded and then displayed/saved using a text editor (default = MS WordPad®). |
| The failure and restart of a V.24 interface generates an entry in the event log and releases a remote error signal (V.24 failure = "Check printer" error message, V.24 restart = Withdrawal of error message). |
| HiPath 3000/5000 V9, Service Documentation, Issue 7 | up ![]() |
|
![]() |
||
| Disclaimer & Copyright | ID: P31003H3590S100017620 | 2012-06-25 |