4.1.4 |
Installing HiPath 3800 (19-Inch Cabinet) |
| This section contains information on how to install the HiPath 3800 communication system in a 19-inch cabinet. This chapter describes the standard installation procedures for the basic system. Refer to Chapter 9 "Expanding and Upgrading HiPath 3000" for information about supplementary equipment or expansions. |
4.1.4.1 |
Selecting the Installation Site |
| The installation site is generally determined by the 19-inch cabinet already installed. |
| The following specifications must be observed when selecting a location: |
| • | The 19-inch cabinets provided for installing the HiPath 3800 components must have the following characteristics: |
| - | Components installed in the 19-inch cabinet must be accessible from both the front and the rear. |
| - | It should be possible to install 19-inch components both at the front and at the rear (
four vertical bars).
|
| - | It is recommended that the width of the cabinet measure 700 to 800 mm; the depth at least 600 mm. Deeper cabinets (800 - 900 mm) make installation, cable servicing, and the installation of additional components in the rear of the cabinet much easier. |
| - | The support brackets required for installing the system cabinets must have a minimum ultimate load of 40 kg. The support brackets must be purchased from the relevant 19-inch cabinet supplier. |
| - | The system cabinets must be fixed to the cabinet bars using the angle brackets included in the delivery. |
| • | One height unit (one height unit is approx. 1.7" = 43 mm) must be kept clear above the cabinet to accommodate the gray plastic cover (Figure 4-9) attached to the top of the system cabinets. Never remove this plastic cover. |
| • | The following minimum clearance must be provided in order to ensure adequate ventilation of the system cabinets in the 19-inch cabinet (see Figure 4-10): |
| - | three height units between two stacked system cabinets. |
| - | one height unit above one system cabinet if a patch panel is being installed, for example. |
| • | To guarantee sufficient heat dissipation, the basic cabinet must be mounted at the lowest position in a 19-inch cabinet. In a 19-inch cabinet with active (heat-emitting) components already installed, the lowest position must be cleared for installation of the basic cabinet. If inactive components (e.g. patch panel) are involved, the basic cabinet can also be installed above them. |
| • | Do not expose the 19-inch cabinet to direct sources of heat (such as sunlight and heaters.). |
| • | Do not expose the 19-inch cabinet to extremely dusty environments. |
| • | Avoid contact with chemicals. |
| • | Take every precaution to prevent the formation of condensation on the system during operation. Systems covered with condensation must be dried before being used. |
| • | Observe the environmental conditions specified in Section 2.11 "Environmental Conditions". |
| Information on the design of the HiPath 3800 can be found in Section 2.1.4.1 "Design and Dimensions of HiPath 3800". |
Examples for installation in a 19-inch cabinet |
|
4.1.4.1.1 |
For U.S. only: Power plug |
| An AC connection is required for each cabinet. The AC connection must fulfill the requirements specified in Table 4-3. |
| |
| The system must be properly grounded before startup (see description in Section 4.1.4.4 "Grounding the System"). |
4.1.4.2 |
Unpacking the Components |
Procedure |
| |
|
4.1.4.3 |
Mounting System Cabinets in the 19-Inch Cabinet |
4.1.4.3.1 |
Introduction |
| The cabinets are not supplied with pre-installed boards. For information on board installation, please see Section 4.1.5 "Installing Boards (Configuration Notes)". |
| If it has been agreed to provide connector panels for connecting peripherals, these are included in the delivery. For information on the installation procedure, please see Section 4.1.5.4 "Mounting Connector Panels (if required)". |
4.1.4.3.2 |
Mounting a System Cabinet using Support and Angle Brackets |
| If a two-cabinet system is to be installed in a 19-inch cabinet, each system cabinet should be installed separately. |
| The following components are required to install a system cabinet: |
| • | Two cabinet-specific support brackets with an ultimate load > 40 kg, which must be provided by the 19-inch cabinet supplier. |
| • | Two angle brackets (order no. C39165-A7075-D1), which are supplied with the system cabinet. |
|
Procedure |
|
|
Installation in the 19-inch cabinet |
4.1.4.4 |
Grounding the System |
| Ground the system as described. |
Grounding: Inspection and Implementation |
| Implementation guidelines in accordance with IEC 60364 and IEC 60950-1 must be adhered to during installation. |
|
||||||||||||||||||||||||||||||||||
|
Grounding the system cabinets and possible patch panels |
Note on possible ground loops |
|
4.1.4.5 |
Checking the Grounding |
Procedure |
| Perform the tests in the table below to ensure that the system is properly grounded before startup. |
|