4.1.3  

Installing HiPath 3800 (Standalone) 
 
This section contains information on how to install the HiPath 3800 communication system. This chapter describes the standard installation procedures for the basic system. Refer to Chapter 9 "Expanding and Upgrading HiPath 3000" for information about supplementary equipment or expansions.

4.1.3.1  

Selecting the Installation Site 

Selecting a site  
The customer usually has a preferred installation site in mind.
Make sure that the customer's site meets the following guidelines:
 •   To guarantee sufficient system ventilation, allow a minimum of 50 mm clearance between the base of the cabinet and the ground and between stacked cabinets.
 •   When cabinets are stacked, the basic cabinet must always be at the bottom of the stack.
 •   Allow a minimum clearance of 10 cm both at the rear and the front of the cabinets for maintaining boards and for wiring.
 •   Do not expose the systems to direct sources of heat (for example sunlight and heaters).
 •   Do not expose the systems to extremely dusty environments.
 •   Avoid contact with chemicals.
 •   Take every precaution to prevent the formation of condensation on the system during operation. Systems covered with condensation must be dried before being used.
 •   Observe the environmental conditions specified in Section 2.11 "Environmental Conditions".
 •   Install additional primary protection.
 •   Avoid standard carpeting, as it tends to produce electrostatic charges.
 •   Ensure the availability of a power source that meets the requirements described in Section 4.1.3.1 "For U.S. only: Power plug".
 •   Ensure that a distance of at least 40 in. (101.6 cm) is left between Siemens Enterprise Communications GmbH & Co. KG equipment and other electrical equipment. The National Electrical Code (NEC) requires 36 in. (91.44 cm) of clearance in front of electrical equipment and 40 in. (101.6 cm) of clearance from other electrical service equipment.
Information on the design of the HiPath 3800 can be found in Section 2.1.4.1 "Design and Dimensions of HiPath 3800".

4.1.3.1.1  

For U.S. only: Power plug 
An AC connection is required for each cabinet. The AC connection must fulfill the requirements specified in Table 4-2.

 Table 4-2   Electrical Connection Values (for U.S. only)
 Nominal voltage  
 Nominal voltage range  
 Nominal Frequency Range  
 Wall Outlet Configurations  
 from  
 to  
 from  
 to  
 120 V AC/60 Hz  
 110 V AC  
 130 V AC  
 47 Hz  
 63 Hz  
NEMA 5-15, 2-pin, 3-wire, earth  
WARNING  
Never connect a HiPath 3800 system or a combination of HiPath 3800 systems directly to a wall socket. Use a UL-listed or CSA-certified surge protector for every two cabinets.  

AC Outlet Requirements  
 •   A UL-listed or CSA-certified surge protector must be connected between the socket and the system. Two cabinets can be connected to each surge protector. Never connect a HiPath 3800 system or a combination of systems directly to a wall socket.
 •   The power source may not be more than 2.4 m (8 ft.) from the system.
 •   The power source must provide 120 V AC (single-phase, fused) power at 50-60 Hz and 20 A.
 •   A warning should be attached to the circuit breaker to prevent accidental removal of power.
 •   An independent electric circuit with an isolated ground conductor should be used.
The system must be properly grounded before startup (see description in Section 4.1.3.4 "Grounding the System").

4.1.3.2  

Unpacking the Components 

Procedure  

 Step  
 Activity  
 1.  
Compare the components with the packing slip or customer receipt to make sure that they are correct and complete.  
 2.  
Determine whether any damage has occurred during transport and report it to the proper departments.  
 3.  
Dispose of the packing materials properly.  
Caution  
Only use tools and equipment that are in perfect condition. Do not use equipment with visible damage.  

4.1.3.3  

Setting up the System Cabinets 

Introduction  
The cabinets are not supplied with pre-installed boards. For information on board installation, please see Section 4.1.5 "Installing Boards (Configuration Notes)".
If it has been agreed to provide connector panels for connecting peripherals, these are included in the delivery. For information on the installation procedure, please see Section 4.1.5.4 "Mounting Connector Panels (if required)".
The front plastic cover (for board servicing) and the rear plastic cover (for cable servicing) are not attached to the system cabinets. Both covers are supplied in separate packages.
Danger  
Be sure to connect the main protective earthing terminal on all system cabinets to the grounding point of the electrical building installation before starting the system and before connecting up the peripherals (for example, potential equalization bus).  
The system may only be started (connected to the power supply) if all system cabinets are sealed at the rear with the connection and filler panels provided.  

4.1.3.3.1  

Overview 

System configurations  
The following setup options are possible for system cabinets:
 •   Single cabinet
 •   Two cabinets (stacked)
 •   Two cabinets (side by side)

4.1.3.3.2  

Setting Up a Single Cabinet 
Caution  
To guarantee sufficient ventilation for the system cabinet, allow a minimum clearance of 50 mm between the base of the cabinet and the ground.  

Procedure  

 Step  
 Activity  
 1.  
Place the system cabinet in the installation site and make sure that it is level and stable.  
 2.  
Check that the space between the base of the cabinet and the ground is at least 50 mm.  
 3.  
If necessary, set up the basic cabinet in the following way:  
 •   Unscrew lock nut (Figure 4-1, A) on one of the cabinet feet using an open-end wrench (wrench size = 13 mm).
 •   Adjust the height of the cabinet foot by turning the screw nut (Figure 4-1, B) so that the cabinet is steady and the minimum clearance is observed.
 •   Fix the cabinet foot in position by tightening the lock nut (Figure 4-1, A).

Basic cabinet setup  
 Figure 4-1   HiPath 3800 - Setting Up the Basic Cabinet
 

4.1.3.3.3  

Stacking Two Cabinets 
Caution  
To guarantee sufficient ventilation for the system cabinets, comply with the following requirements:  
 •   The basic cabinet must be set up as the bottom cabinet.
 •   Allow a minimum of 50 mm clearance between the base of the cabinet and the floor, and between basic and expansion cabinets.

Procedure  

 Step  
 Activity  
 1.  
Place the system cabinet in the installation site and make sure that it is level and stable.  
 2.  
Check that the space between the base of the basic cabinet and the ground is at least 50 mm.  
 3.  
If necessary, set up the basic cabinet in the following way:  
 •   Unscrew lock nut (Figure 4-1, A) on one of the cabinet feet using an open-end wrench (wrench size = 13 mm).
 •   Adjust the height of the cabinet foot by turning the screw nut (Figure 4-1, B) so that the cabinet is steady and the minimum clearance is observed.
 •   Fix the cabinet foot in position by tightening the lock nut (Figure 4-1, A).
 4.  
Place the expansion cabinet on top of the basic cabinet.  
The cabinet feet have indents. When placing the expansion cabinet on top of the basic cabinet, ensure that these indents are sitting precisely on top of the screw heads in the four corners of the basic cabinet (Figure 4-2).  
 5.  
Check that the space between the base of the basic cabinet and the ground is at least 50 mm.  
 6.  
If necessary, set up the expansion cabinet as described in Step [3].  

Positioning the cabinet feet  
 Figure 4-2   HiPath 3800 - Positioning the Cabinet Feet
 

Installing a stacked two-cabinet system  
 Figure 4-3   HiPath 3800 - Installing a Stacked Two-Cabinet System (Rear View)
 

4.1.3.3.4  

Setting Up a Two-Cabinet System Side by Side 
Caution  
To guarantee sufficient ventilation in the system cabinets, allow a minimum clearance of 50 mm between the base of the cabinets and the ground.  

Procedure  

 Step  
 Activity  
 1.  
Place the system cabinet in the installation site and make sure that it is level and stable.  
 2.  
Check that the space between the base of the basic cabinet and the ground is at least 50 mm.  
 3.  
If necessary, set up the basic cabinet in the following way:  
 •   Unscrew lock nut (Figure 4-1, A) on one of the cabinet feet using an open-end wrench (wrench size = 13 mm).
 •   Adjust the height of the cabinet foot by turning the screw nut (Figure 4-1, B) so that the cabinet is steady and the minimum clearance is observed.
 •   Fix the cabinet foot in position by tightening the lock nut (Figure 4-1, A).
 4.  
Place the expansion cabinet beside the basic cabinet.  
Note: The cabinets can be placed directly beside one another.  
 5.  
Check that the space between the base of the expansion cabinet and the ground is at least 50 mm.  
 6.  
If necessary, set up the expansion cabinet as described in Step [3] ensuring that both cabinets are at exactly the same level.  

Installing a Two-Cabinet System Side by Side  
 Figure 4-4   HiPath 3800 - Installing a Two-Cabinet System Side by Side (Rear View)
 

4.1.3.4  

Grounding the System 
Ground the system as described.

4.1.3.4.1  

Not for U.S.: Grounding the System 

Grounding: Grounding options  
Implementation guidelines in accordance with IEC 60364 and IEC 60950-1 must be adhered to during installation.
Danger  
Each HiPath 3800 system cabinet and all external main distribution frames (for example, MDFU-E) must be grounded as shown in Figure 4-5 by a separate ground conductor (minimum cross-section = 2.5 mm2). Make sure that the ground conductor is securely installed and strain-relieved.  
If external factors can impact on the ground conductor and if protected installation is not possible, the ground conductor must have a minimum cross-section of 4 mm2.  
Failure to follow these instructions can result in electrical shock.  
The illustrations starting with Figure 4-6 show different grounding options.
Danger  
If your personnel are not qualified to work on the low-voltage network (230 Vac), you must hire a licensed electrician to ground the system separately using option 1b (Figure 4-7). The Section 1.6.1 "Connection to the Power Circuit" is to be adhered to.  

Note on possible ground loops  
To avoid ground loops from remotely operated devices (V.24 system peripherals), the devices should be connected to the same low-voltage network (sub-distribution board) if possible.
If the building floor plan does not permit this, you may need a line driver to isolate the external devices in the event of a malfunction.  

Grounding the system(s) and a possible main distribution frame  
 Figure 4-5   HiPath 3800 - Grounding the System Cabinets and Main Distribution Frame (nor for U.S.)
 

Grounding option 1a  
 Figure 4-6   HiPath 3800 - Grounding Option 1a (not for U.S.)
 

Grounding option 1b  
 Figure 4-7   HiPath 3800 - Grounding Option 1b (not for U.S.)
 

4.1.3.4.2  

For U.S. only: Grounding the System 
Implementation guidelines in accordance with NEC (National Electrical Code), UL 60950-1 and IEC 60364 must be adhered to during installation.
A connecting cable is used for grounding the system cabinets. The system must also be grounded by a separate ground conductor. Choose a ground connection with less than 2 ohms of resistance, such as:
 •   Master ground busbar
 •   Ground field
 •   Copper ground rod
Run a separate earth ground conductor from the earth ground to the cabinet frame ground (located in the lower right corner of the backplane). The minimum cross-section required is 12 AWG.
Figure 4-8 shows the safety conductor connectors for the basic cabinet. An expansion cabinet requires a separate earth ground.
 Figure 4-8   HiPath 3800 - Earth ground connection (for U.S. only)
 
DANGER  
This wire installation must be completed by a qualified electrician and must comply with the national and local electrical codes. The Section 1.6.1 "Connection to the Power Circuit" is to be adhered to.  

Grounding the Main Distribution Frame  
Mount and ground the MDF in accordance with the manufacturer's instructions.

4.1.3.5  

Checking the Grounding 

Procedure  
Perform the tests in the table below to ensure that the system is properly grounded before startup.

 Step  
 Activity  
 Target  
 1.  
Check the ohmic resistance of the ground connection to the system:  
Perform measurement between the PE (protective earth) on a socket in the internal installation (at the system's installation site) and HiPath 3800.  
 
Prerequisites:  
 •   HiPath 3800 is not yet connected to the low-voltage network via the power cable.
 •   The system's separate grounding is connected.
 < 10 ohms  
 2.  
Check the ohmic resistance between the individual system parts (basic cabinet, expansion cabinet, main distribution frame).  
 
Prerequisite:  
HiPath 3800 is not yet connected to the low-voltage network via the power cable.  
 < 1 ohm