4.1.3 |
Installing HiPath 3800 (Standalone) |
| This section contains information on how to install the HiPath 3800 communication system. This chapter describes the standard installation procedures for the basic system. Refer to Chapter 9 "Expanding and Upgrading HiPath 3000" for information about supplementary equipment or expansions. |
4.1.3.1 |
Selecting the Installation Site |
Selecting a site |
| The customer usually has a preferred installation site in mind. |
| Make sure that the customer's site meets the following guidelines: |
| • | To guarantee sufficient system ventilation, allow a minimum of 50 mm clearance between the base of the cabinet and the ground and between stacked cabinets. |
| • | When cabinets are stacked, the basic cabinet must always be at the bottom of the stack. |
| • | Allow a minimum clearance of 10 cm both at the rear and the front of the cabinets for maintaining boards and for wiring. |
| • | Do not expose the systems to direct sources of heat (for example sunlight and heaters). |
| • | Do not expose the systems to extremely dusty environments. |
| • | Avoid contact with chemicals. |
| • | Take every precaution to prevent the formation of condensation on the system during operation. Systems covered with condensation must be dried before being used. |
| • | Observe the environmental conditions specified in Section 2.11 "Environmental Conditions". |
| • | Install additional primary protection. |
| • | Avoid standard carpeting, as it tends to produce electrostatic charges. |
| • | Ensure the availability of a power source that meets the requirements described in Section 4.1.3.1 "For U.S. only: Power plug". |
| • | Ensure that a distance of at least 40 in. (101.6 cm) is left between Siemens Enterprise Communications GmbH & Co. KG equipment and other electrical equipment. The National Electrical Code (NEC) requires 36 in. (91.44 cm) of clearance in front of electrical equipment and 40 in. (101.6 cm) of clearance from other electrical service equipment. |
| Information on the design of the HiPath 3800 can be found in Section 2.1.4.1 "Design and Dimensions of HiPath 3800". |
4.1.3.1.1 |
For U.S. only: Power plug |
| An AC connection is required for each cabinet. The AC connection must fulfill the requirements specified in Table 4-2. |
| |
|
AC Outlet Requirements |
| • | A UL-listed or CSA-certified surge protector must be connected between the socket and the system. Two cabinets can be connected to each surge protector. Never connect a HiPath 3800 system or a combination of systems directly to a wall socket. |
| • | The power source may not be more than 2.4 m (8 ft.) from the system. |
| • | The power source must provide 120 V AC (single-phase, fused) power at 50-60 Hz and 20 A. |
| • | A warning should be attached to the circuit breaker to prevent accidental removal of power. |
| • | An independent electric circuit with an isolated ground conductor should be used. |
| The system must be properly grounded before startup (see description in Section 4.1.3.4 "Grounding the System"). |
4.1.3.2 |
Unpacking the Components |
Procedure |
| |
|
4.1.3.3 |
Setting up the System Cabinets |
Introduction |
| The cabinets are not supplied with pre-installed boards. For information on board installation, please see Section 4.1.5 "Installing Boards (Configuration Notes)". |
| If it has been agreed to provide connector panels for connecting peripherals, these are included in the delivery. For information on the installation procedure, please see Section 4.1.5.4 "Mounting Connector Panels (if required)". |
| The front plastic cover (for board servicing) and the rear plastic cover (for cable servicing) are not attached to the system cabinets. Both covers are supplied in separate packages. |
4.1.3.3.1 |
Overview |
System configurations |
| The following setup options are possible for system cabinets: |
| • | Single cabinet |
| • | Two cabinets (stacked) |
| • | Two cabinets (side by side) |
4.1.3.3.2 |
Setting Up a Single Cabinet |
|
Procedure |
|
Basic cabinet setup |
4.1.3.3.3 |
Stacking Two Cabinets |
|
Procedure |
|
Positioning the cabinet feet |
Installing a stacked two-cabinet system |
4.1.3.3.4 |
Setting Up a Two-Cabinet System Side by Side |
|
Procedure |
|
Installing a Two-Cabinet System Side by Side |
4.1.3.4 |
Grounding the System |
| Ground the system as described. |
4.1.3.4.1 |
Not for U.S.: Grounding the System |
Grounding: Grounding options |
| Implementation guidelines in accordance with IEC 60364 and IEC 60950-1 must be adhered to during installation. |
|
| The illustrations starting with Figure 4-6 show different grounding options. |
|
Note on possible ground loops |
|
Grounding the system(s) and a possible main distribution frame |
Grounding option 1a |
Grounding option 1b |
4.1.3.4.2 |
For U.S. only: Grounding the System |
| Implementation guidelines in accordance with NEC (National Electrical Code), UL 60950-1 and IEC 60364 must be adhered to during installation. |
| A connecting cable is used for grounding the system cabinets. The system must also be grounded by a separate ground conductor. Choose a ground connection with less than 2 ohms of resistance, such as: |
| • | Master ground busbar |
| • | Ground field |
| • | Copper ground rod |
| Run a separate earth ground conductor from the earth ground to the cabinet frame ground (located in the lower right corner of the backplane). The minimum cross-section required is 12 AWG. |
| Figure 4-8 shows the safety conductor connectors for the basic cabinet. An expansion cabinet requires a separate earth ground. |
|
Grounding the Main Distribution Frame |
| Mount and ground the MDF in accordance with the manufacturer's instructions. |
4.1.3.5 |
Checking the Grounding |
Procedure |
| Perform the tests in the table below to ensure that the system is properly grounded before startup. |
|