3.2.6  

CUC and CUCR 
 
The backplane comes in two versions:
 •   CUC (Connection Unit Com) S30777-Q750-X (Figure 3-9) - for use in HiPath 3550 (wall housing)
 •   CUCR (Connection Unit Com Rack) S30777-Q750-Z (Figure 3-10) - for use in HiPath 3500 (19-inch housing)

CUC connector designations and slot assignments (S30777-Q750-X)  
 Figure 3-9   CUC Backplane (S30777-Q750-X)
 

CUCR connector designations and slot assignments (S30777-Q750-Z)  
 Figure 3-10   CUCR Backplane (S30777-Q750-Z)
 

Replacing the Backplane  
Replacing the backplane may be necessary due to contact problems. These are evidenced by the following symptoms:
 •   Error messages about various peripheral modules occur.
 •   Erratic error messages about the CBCC/CBRC and UPSCD modules occur.
 •   The system zdisplays the error message B16-12 RESTART: Power down and performs a restart.
Please note, however, that the backplane should only be replaced if the errors still occur even after the following points have been checked and the mentioned problems eliminated:
 •   Have the necessary grounding regulations been followed?
 •   Do the cables have contact problems or visible damage?
 •   Do the system components have any visible damage?
The following part numbers must be used to order the necessary replacement parts for HiPath 3500:
L37911-A10-A18:  
HiPath 3500 Box, incl. UPSCDR  
S30777-Q750-Z:  
HiPath 3500 Backplane CUCR  
Replacing the backplane is described in Section 4.2.5 "Replacing the Backplane".