3.3.46 |
TS2N (old: TS2) [Not for U.S.], TS2R (not for U.S.) |
|
Introduction |
| The board contains a four-wire interface with S2M code for connection to the public telecommunications network or private networks. |
| Up to thirty trunk calls can be conducted simultaneously via the S2M interface. The total transmission speed including signaling and synchronization is 2048 Mbps. |
| Two trace files are available: |
| • | Implemented up to and including V4.0: |
| - | TS2 (Trunk Module S2M) S30810-Q2913-X100 (Figure 3-118) - for use in HiPath 3550 (wall housing) |
| - | TS2R (Trunk Module S2M Rack) S30810-K2913-Z100 (Figure 3-119) - for use in HiPath 3500 (19-inch housing) |
| • | Implemented in V5.0 and later: |
| - | TS2N (old: TS2) [Trunk Module S2M] S30810-Q2913-X300 (Figure 3-118) - for use in HiPath 3550 (wall housing) |
| - | TS2R (Trunk Module S2M Rack) S30810-K2913-Z300 (Figure 3-119) - for use in HiPath 3500 (19-inch housing) |
| Board usage is subject to the following restrictions: |
| • | Only one TS2N/TS2R board allowed (primary multiplex access) |
| • | For slot 7 or 9 only |
| To support country-specific CAS protocols, you can use the Euro-ISDN CAS gateway ECG. The ECG cabinet is a protocol converter that converts the Euro-ISDN protocol into the Channel Associated Signaling CAS protocol. Refer to the installation instructions, which are provided with each ECG cabinet, for information on the connection and power supply. For HiPath 3000 V1.0 and later, you can also use the new TMCAS board to support country-specific CAS protocols. |
TS2N interfaces (old: TS2) |
TS2R interfaces |
Network interfaces |
| The TS2N board is connected to the network transfer point (NT1) via the symmetrical line (120 ohms, four-wire twisted-pair cable) at X2 or via an MW line at X5. |
| Note: use the connection kits listed on Page 3-347 for NT connections in Spain and Portugal. |
| • | Symmetrical line (120 ohms) The maximum cable length (approx. 130 m) depends on the quality of the cable used and its signal attenuation. Use shielded cables only to guarantee proper operation. |
| Connect the cable to the X2 using an 8-pin Wieland terminal (TS2N only). |
| • | MW line (MW8 (RJ48C)jack) The shielded 8-pin MW8 (RJ48C) jack X5 is provided for connecting MW lines. The maximum cable length (approx. 100 m) depends on the quality of the cable used and its signal attenuation. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||
S2M trunk connection |
| Keep the cable from the NT to HiPath 3550 or HiPath 3500 as short as possible to ensure proper operation. |
|
| NT1 power supply |
| • | TS2N board The NT1 supply voltage of -48 V can be tapped from the X2 connector (see Table 3-168). There is a power limit of < 15 W for this voltage, which the system feeds over the CUC. |
| • | TS2R board The NT1 power supply must come from an S30122-X7321-X (S30122-X7321-X100 with UPS operation) power supply unit. |
Cable set for NT connections (Spain and Portugal only) |
| Connection kit contents and part numbers: |
| • | TS2N/TS2R connection kit for Spain and Portugal: F50035-E2-X63 containing the following: |
| - | Interface converter: S30122-X7357-X |
| - | Cable 1 = Patch cable MW8 (RJ48C), 10 m: C39195-Z7208-A100 |
| - | Cable 2 (2 units) = coaxial adapter cable, 30 cm: S30267-Z354-A3 |
| • | TS2N/TS2R upgrade kit for Portugal: L30252-U600-A190 containing the following: |
| - | Cable 3 (2 units) = Mini-coaxial cable, 10 cm: S30267-Z353-A1 |