3.3.28 |
TCAS-2 and TCASR-2 (for selected countries only) |
|
Introduction |
| The following cards - one per system - can be used for V5.0 SMR -10 and later to support country-specific CAS (Channel Associated Signaling) protocols: |
| • | TCAS-2 (S30810-Q2945-X) in HiPath 3550 |
| • | TCASR-2 (S30810-K2945-X) in HiPath 3500 |
| Please note that the cards listed can only be used in slots 7 and 9. |
| Each of the cards features two E1-CAS interfaces, which together support up to 60 B channels. Since HiPath 3550 and HiPath 3500 each support a maximum of 30 B channels, a total of up to 30 B channels can be used per card. |
| Direct connection to the MINI BNC connectors on each card is only possible for coaxial trunks (75 ohms). An external impedance converter (F31505-E1-A146) must be used for symmetrical trunks (120 ohms). |
| TCAS-2 and TCASR-2 function as converters, which convert the Euro-ISDN protocol on an S2M link to the Channel Associated Signaling protocol CAS. In contrast to the predecessor TMCAS card, TCAS-2 and TCASR-2 communicate directly with the central control in the system. All signaling and data traffic goes through TCAS-2 and TCASR-2. Unlike TMCAS, connection to an S2M card is therefore not required. |
Interfaces and Jumpers |
Settings |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||
Connections |
TCASR-2 front panel |
Seven-segment display |
| The card's software status can be ascertained on the basis of the seven-segment display. For this a distinction is made between the following boot phases: |
|
| • | U-boot (firmware) states |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| • | Linux operating system states |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| • | CAS application software states |
Modem (optional) |
| The analog modem (modem kit F31505-E1-A147) is an optional submodule for the TCAS-2 and TCASR-2 cards, which is plugged into the X20 and X21 ports. This facilitates remote administration of the CAS protocol converter on the TCAS-2 and TCASR-2 cards (see Page 3-252). |
Administration of the CAS protocol converter |
| A separate tool, the CAS Manager, is used to download the software and administer the TCAS-2 and TCASR-2. The CAS Manager software is stored on a CD supplied with the card. For information on how to install the CAS Manager software on the Service PC, refer to the readme file. |
| The following options are available for accessing the cards: |
| • | Via the V.24 interface (9-pin MINI DIN jack X803) and the connection cable C39195-A9700-B532. |
| • | Via the Ethernet (10/100BaseT) interface (RJ45 jack X804). |
| • | Via the optional analog modem (modem kit F31505-E1-A147). In this case, you will need to establish a connection from the analog modem (RJ45 jack X805) to a free port in an analog subscriber line module via the RJ45 cable C39195-Z7208-A10 supplied with the modem kit (see Figure 3-85). |
Assigning the CAS cable |
| The following options are available for connecting network terminators (NT), multiplexers (MUX) or modems to the TCAS-2 and TCASR-2 cards (MINI BNC connections): |
| • | Coaxial trunk (75 ohms), length = 10 m |
| • | symmetrical line (120 ohms) |
| The impedance converter F31505-E1-A146 must be used for connecting to a symmetrical trunk. |
| • | CAS cable shield contacts |
| To ensure sufficient electromagnetic shielding (according to EN 55022), both shielded CAS cables must be contacted at the appropriate points on the HiPath 3550/HiPath 3350. |
| Procedure: |
| Fix the cable shielding (B) for both CAS cables (A) via cable binder (C) to the T tongue (D) of the housing, so a continuously conductive contact is created between the conductive tape on the cable shielding and the housing (see figure). |