3.3.11  

SLAD4, SLAD8, SLAD8R 
 
NOTE  
Danger of damage to property due to surge voltage. The required lightning protection measures must be taken for this board, see Section 2.1.2 "Lightning Protection".  

Introduction  
From HiPath 3000/5000 V6 R4 and V7 R4 or higher the following boards can be used to connect analog stations (analog telephones, fax group 3 etc.):
 •   SLAD4 (Subscriber Line Analog with DuSLIC) S30810-H2956-X100 - for HiPath 3550 and HiPath 3350
 •   SLAD8 (Subscriber Line Analog with DuSLIC) S30810-H2956-X200 - for HiPath 3550 and HiPath 3350
 •   SLAD8R (Subscriber Line Analog with DuSLIC Rack) S30810-K2956-X300 - for
HiPath 3500 and HiPath 3300
The SLAD boards are compatible successor modules for the following boards:
 •   4SLA (S30810-Q2923-X200)
 •   8SLA (S30810-Q2923-X100)
 •   8SLAR (S30810-K2925-Z).
These are being phased out and can no longer be ordered.

Main features  
A DTMF code receiver is available for each analog interface (permits DTMF dialing at analog telephones). This guarantees that all analog terminals connected are fully accessible.
These boards support calling name identification presentation (CLIP).
The connection of external extensions via OPS (Off-Premises Station) signaling is supported.
Ring voltage is generated by the power supply unit of the relevant system (UPSC-D for SLAD4 and SLAD8, UPSC-DR for SLAD8R). Please refer to Section 2.8 "Country-Specific Ring Frequencies for Analog Subscriber Line Modules" for information on how to set the country-specific ring frequency.

SLAD4, SLAD8 interfaces  
 Figure 3-46   SLAD4, SLAD8 - interfaces
 

 Table 3-56   SLAD4, SLAD8 - assigning the ports
 X2, Pin  
 T/R ports 1-4  
 X3, Pin  
 T/R ports 5-8  
 1  
 a 1  
 1  
 a 5  
 2  
 b 1  
 2  
 b 5  
 3  
 a 2  
 3  
 a 6  
 4  
 b 2  
 4  
 b 6  
 5  
 a 3  
 5  
 a 7  
 6  
 b 3  
 6  
 b 7  
 7  
 a 4  
 7  
 a 8  
 8  
 b 4  
 8  
 b 8  
For U.S. only:  
For SLAD4 and SLAD8, external extensions to the a/b ports can be connected through OPS signaling (hereinafter called OPS ports). The number of OPS ports is limited. The following maximum values must not be exceeded:  
 •   in HiPath 33x0: max. 4 OPS ports
 •   in HiPath 35x0: max. 8 OPS ports and max. 4 OPS ports per board
OPS ports are generally prohibited at SLAD16.  

SLAD8R interfaces  
 Figure 3-47   SLAD8R - interfaces
 

 Table 3-57   SLAD8R - assigning the ports
 MW8 jack  
 X2, Pin  
 T/R ports 1-4  
 MW8 jack  
 X2, Pin  
 T/R ports 5-8  
 1  
 14  
 a 1  
 5  
 54  
 a 5  
 15  
 b 1  
 55  
 b 5  
 2  
 24  
 a 2  
 6  
 64  
 a 6  
 25  
 b 2  
 65  
 b 6  
 3  
 34  
 a 3  
 7  
 74  
 a 7  
 35  
 b 3  
 75  
 b 7  
 4  
 44  
 a 4  
 8  
 84  
 a 8  
 45  
 b 4  
 85  
 b 8