3.3.11 |
SLAD4, SLAD8, SLAD8R |
|
Introduction |
| From HiPath 3000/5000 V6 R4 and V7 R4 or higher the following boards can be used to connect analog stations (analog telephones, fax group 3 etc.): |
| • | SLAD4 (Subscriber Line Analog with DuSLIC) S30810-H2956-X100 - for HiPath 3550 and HiPath 3350 |
| • | SLAD8 (Subscriber Line Analog with DuSLIC) S30810-H2956-X200 - for HiPath 3550 and HiPath 3350 |
| • | SLAD8R (Subscriber Line Analog with DuSLIC Rack) S30810-K2956-X300 - for HiPath 3500 and HiPath 3300 |
| The SLAD boards are compatible successor modules for the following boards: |
| • | 4SLA (S30810-Q2923-X200) |
| • | 8SLA (S30810-Q2923-X100) |
| • | 8SLAR (S30810-K2925-Z). |
| These are being phased out and can no longer be ordered. |
Main features |
| A DTMF code receiver is available for each analog interface (permits DTMF dialing at analog telephones). This guarantees that all analog terminals connected are fully accessible. |
| These boards support calling name identification presentation (CLIP). |
| The connection of external extensions via OPS (Off-Premises Station) signaling is supported. |
| Ring voltage is generated by the power supply unit of the relevant system (UPSC-D for SLAD4 and SLAD8, UPSC-DR for SLAD8R). Please refer to Section 2.8 "Country-Specific Ring Frequencies for Analog Subscriber Line Modules" for information on how to set the country-specific ring frequency. |
SLAD4, SLAD8 interfaces |
| |
SLAD8R interfaces |
| |
| HiPath 3000/5000 V9, Service Documentation, Issue 7 | up ![]() |
|
![]() |
||
| Disclaimer & Copyright | ID: P31003H3590S100017620 | 2012-06-25 |