3.2.11 |
LIMS |
|
Introduction |
| The LAN Interface Module for SAPP LIMS (S30807-Q6721-X) is an optional plug-in card for the CBSAP central control board in HiPath 3800. |
| The board provides two Ethernet (10BaseT) LAN connectors via two 8-pin RJ45 jacks: |
| • | LAN1 (administration via HiPath 3000/5000 Manager E and CTI functions) |
| • | LAN2 (not assigned) |
| The LIMS module can, for example, be used for the following applications: |
| - | For administration using HiPath 3000/5000 Manager E |
| - | For the TAPI 120/170 connection via the CSTA interface. Bear in mind, however, that the number of BHCAs (Busy Hour Call Attempts = number of connection attempts during busy traffic hours) is restricted to 400 at a maximum of six CSTA links for the TAPI 120/170 connection. The use of "power dialers" is not approved. |
| - | For the output of call data |
| In V6.0 or later, the system software deactivates an existing LIMS module when an STMI2 board is inserted. You cannot operate the LIMS module and an STMI2 board simultaneously in a HiPath 3800. |
RJ45 jack assignment |
| |
| HiPath 3000/5000 V9, Service Documentation, Issue 7 | up ![]() |
|
![]() |
||
| Disclaimer & Copyright | ID: P31003H3590S100017620 | 2012-06-25 |