9.9.2  

Actuators 
 


Settings | Auxiliary equipment | Actuators
 
With Hicom 150 E Office Point, Hicom 150 E Office Com and HiPath 3300 to 3550, the optional control relay module can be implemented with 4 control inputs and outputs each for functions such as monitoring, alarm, control and adjustment. This can be used in security systems or building management systems.
The signal input function (control input) is triggered by closing any of the external floating contacts. The external electric circuit is supplied by the control relay module and electrically isolated from the system controller by means of an opto-coupler.

9.9.2.1  

Actuator list table 
The actuators to be administered are displayed in the list. When you select an actuator in the list, the parameters for that actuator are displayed in the Actuator area and can be modified.

9.9.2.2  

Area: Actuator 

Actuator type  
Various functions can be assigned to the actuators (relays).

Type  
Function  
Switching time  
No function  
The relevant actuator is either not operating or is entered as a common ringer under Settings | Incoming calls, call destination lists.
Manual on/off  
The relay can be activated or deactivated for switching purposes by means of the codes 'Activate or deactivate selected switch'. In the case of key terminals this function can also be programmed on a key. A specific station, a group or all stations can be allocated to this relay type by selecting `NONE'. In the case of this relay type, shutdown can be delayed if a value greater than 0 has been entered in the `Switching time' field.
a multiple of 100 ms.
Auto off on timeout  
The relay can be activated or deactivated as a time switch by means of the code `Activate selected switch' (see above).
In the case of key terminals this function can also be programmed on a key.
A specific station, a group or all stations can be allocated to this relay type by selecting `NONE'.
a multiple of 100 ms.
Door opener  
Refer to type Auto off on timeout.
The text "Door opener" is displayed for the allocated terminals.
Speaker amplifier  
The relay is activated when connected to the entrance telephone.
The relay is deactivated when disconnected from the entrance telephone or entrance phone/loudspeaker.
This makes it possible to control an entrance telephone amplifier so that it is only activated when required. An entrance telephone or the loudspeaker port must be allocated to this relay type.
Engaged display  
The relay is activated if the allocated station ceases to be in the idle condition.
In other words: The handset has been picked up, the loudspeaker is activated or the extension is being called. The relay is deactivated if the allocated station resumes the idle condition. This means that the handset has been replaced, the loudspeaker has been deactivated and the extension is not being called. The relay can also be activated directly by means of the code 'Activate/deactivate selected switch'. In the case of system telephones this function can also be programmed on a key. If the relay was activated by means of a code or a key, the status of the allocated station is ignored and the relay can only be deactivated again by means of a code or a key. Practical application: Door busy indicator "Do not disturb", "Meeting", "Conference", PC connection for data transmission (power management). A specific station must be allocated to this relay type. In the case of this relay type, shutdown can be delayed if a value greater than 0 has been entered in the `Switching time' field.
a multiple of 100 ms.
Music On Hold  
The relay is activated if at least one station or a line in the communication system is not in the idle state.
The relay is deactivated if all stations and lines in the communication system are in the idle state.
Practical application: activation of a tape device, CD player, PC connection power management etc.
`NONE' must be entered as allocated station for this relay type and it must only occur once in the communication system.
In the case of this relay type, shutdown can be delayed if a value greater than 0 has been entered in the `Switching time' field.
a multiple of 100 ms.
Second ringer  
(Second ringer (W2))
The relay is activated for the allocated station if it is being called. This relay is deactivated when the called party answers or the call is terminated. This relay is not clocked. A specific station must be allocated to this relay type. In the case of this relay type, shutdown can be delayed if a value greater than 0 has been entered in the `Switching time' field.
a multiple of 3 seconds.
Call charge pulse  
The relay is clocked in accordance with the number for the allocated station on the basis of the incoming call charge pulses or call charge signals. A specific station must be allocated to this relay type. The switching time is not taken into consideration in this case.
always 150 ms pulse and 150 ms break.
Station active  
The relay is activated if the allocated station is active. This means that the handset has been picked up or the loudspeaker has been activated. The relay is deactivated if the allocated station resumes the idle condition. This means that the handset has been replaced or the loudspeaker has been deactivated. A specific station must be allocated to this relay type. In the case of this relay type, shutdown can be delayed if a value greater than 0 has been entered in the `Switching time' field.
a multiple of 100 ms.

Actuator name  
Any name (up to 16 characters in length) can be assigned to the actuators to be administered.

Allocated station, call number  
A station that is to be allocated to an actuator can be selected here.

Switching time, factor  
Timeouts can be entered here as factors to yield multiples of 100 ms.

See also:  
   -   Section 9.6 "Settings | Incoming calls"
   -   Section 9.9 "Settings | Auxiliary equipment"
   -   Section 9.9.6 "Sensors"
   -   HiPath 3000/5000 Feature Description, Actuators