12.1.2  

Program options Save options 
 


Options | Program options | Save options
 
Save Options can be used to set the paths for saving files.

12.1.2.1  

Areas: Automatic File Creation, File Name 
These settings are used to set the options for saving the CDB and other files.

ASCII File
The ASCII file contains the station and trunk capacity of the communication system in tabular form. It can be used as an interface file for other network management tools.
If the switch is activated, a file is created with the name of the CDB and the extension .txt.
Log File
A log file is created in any case.
If the switch is activated, the file is created automatically for the changes made via the HiPath 3000 Manager. (Delta Log File)
The number of log files can be changed via the ini file (see alsoFile ass_150e.ini). To do this, change the value for "MaxLogFile=20" under the "General Settings" section of the ini file. Between 1 and 999 log files can be created. The standard entry is 999 log files.
The file name depends on the access of the communication system. The same mechanism is used as for the CDB. If the access is ISDN, for example, the name consists of the call number, the numbering (001 = current log file) and the ending LOG (e.g., call number = 879, log file: "879.001.log")
If the switch isn't activated, you will be prompted for the name of the LOG file after the data has been transferred. If the dialog box is terminated, the LOG file is created with the name "Delta.log".
Last Load
If the switch is activated, a CDB loaded from a communication system is always named lastload.kds by default.
Customer name
If this switch is activated, each CDB loaded from the communication system is generated using the customer name entered in the "Customer name" field under "Settings | System Parameters | System settings".
Example: A customer called SIEMENS is generated as SIEMENS.kds .
Note: If the "Customer name" field is empty, the name is set to the default lastload.kds .
Counter
If the switch is activated, each CDB that is loaded from the communication system is provided with a sequential counter: customer name.001.kds. 001 is always the most recent CDB.
Depending on the access method, the customer name is as follows:
   -   Access via V.24: direct
   -   Access via IP: 139.255.255.255
   -   Access via ISDN/IMOD: 02302667879
Counter and Last Load
This is the combination of the last load and counter, and the default CDB is then named lastload.001.kds .
Copies  
If the counter reaches the number of copies, the CDB counting starts again at zero.  
If option Lastload or option Customer name is active for Filename, the storage options are fixed and cannot be altered.

12.1.2.2  

Area: Save options for paths 
These settings are used to set the paths for saving the CDB and other files. You can select the appropriate path in each case via ....

Path for CDB  
Path for saving and opening the CDB file (only when using the Save as and Open customer database functions).  
Note: If the Save customer database function is used, the CDB is always saved under the following path: C:\Documents and Settings\User\Application Data\Siemens\Manager E  
Path for ASCII  
Path for saving the ASCII file  
Path for LOG  
Path for saving the delta log file  

ARP Request  
(only for communication systems with connected V.24E COM server)
If this option is activated, an entry is made in the local ARP table of the PCs. The IP address under "IP Parameter/IP Interface" is linked with the MAC address of the communication system. The automatic update of the local ARP table makes initial configuration of the V.24E easier.

See also:  
   -   Section 1.6 "File ass_150e.ini"
   -   Section 12.1 "Program Options"
   -   Section 12.1.1 "Program options General"
   -   Section 12.1.3 "Program options Communication"
   -   Section 12.1.4 "Program options ISDN"