5.3.22  

CLIP no screening 
 
Implementing features, see also Manager E CLIP no screening

Definition  
The essential characteristic of this feature is that the HiPath 3000/5000 "System number - outgoing" does not have to be the same as the "International/national system number - incoming".
To make this possible, the "System number" parameter that has been used until now has been split into "System number - incoming" and "System number - outgoing" for V3.0 SMR 3 and later.
Incoming and outgoing calls usually use the same system number. In this case, the entry under "System number - outgoing" is either empty or the same as the one under "System number- incoming". If this is not the case, you can
 •   enter a different number under "System number - outgoing".
 •   use the routing parameter "No. and type, outgoing" to define whether the entered "System number - outgoing" contains the station number without area code (subscriber), with area code (national), or also with the international country code (international).
You can also activate the flag "Suppress station number" for special customer applications. This prevents the system from sending out the DID number of the station along with the "Station number - outgoing".
Example: You want to prevent customers from directly reaching a service staff member who is reached centrally with a general service number. To conceal his or her own DID number, enter the general service number as "System number - outgoing" and activate the "Suppress station number" flag. Then called subscribers see only the general service number on their display as the CLIP.
In a Centrex environment, you generally enter the number of the Centrex group as "System number - outgoing" and deactivate the "Suppress station number" flag. The called subscriber then sees the Centrex number plus station DID number as the CLIP.
If the entry under "System number - outgoing" is empty, the system automatically sends the entries under "System number - incoming".

Model-Specific Data  

 Subject  
 HiPath 3800  
 HiPath 3550  
 HiPath 3500  
 HiPath 3350  
 HiPath 3300  
Feature available in  
 x  
 x  
 x  
Hardware requirements  
 digital trunk connection  
Software requirements  
 V5.0 or later  
 V3.0 SMR3 or later  
 V3.0 SMR3 or later  

Dependencies/Restrictions  

 Subject  
 Dependency/Restriction  
CLIP no screening  
You must configure the "no screening" option for the trunk connection in the public exchange.