12.4.2 |
Recording HiPath 3000 Board Status |
12.4.2.1 |
Central Control Boards |
Run LED |
| A RUN LED that displays the system's operating capacity is located on the central control board. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Options available? |
| You can call up the following options using the HiPath 3000/5000 Manager E: |
| • | CMA |
| • | CMS |
| • | LIM |
| • | IMODN |
| • | Announcement and music modules: |
| - | MPPI (Product of BEYERTONE GmbH) |
| - | MUSIC (Product of Sound Player GmbH) |
| - | UAM (only with HiPath 3550, HiPath 3350) or UAMR (only with HiPath 3500, HiPath 3300) |
| The availability of one of these announcement and music modules is displayed as "Option 5". The ALUM4 module cannot be displayed. |
12.4.2.2 |
Power Supplies |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||
12.4.2.3 |
Peripheral boards |
Viewing peripheral board status |
| You can use HiPath 3000/5000 Manager E or Assistant T to view the status of all peripheral boards. Display is limited to the following statuses per board: |
| • | Board not inserted |
| • | Board defective (not loaded) |
| • | Board disabled |
| • | Board enabled (active) |
| • | Board busy (at least one station or line from this board is disconnected, is being called, or is busy). |
| For ISDN boards, the status of the reference clock is displayed: |
| • | No reference clock |
| • | Reference clock for clock generator is created. |
| When viewing the board status using the HiPath 3000/5000 Manager E, all peripheral boards integrated into the system are presented in a table. The status display is updated every 3 seconds. |
| With Assistant T, you can only view the status of one board at a time. You can also update the status display by pressing a key. |
| You cannot perform additional activities with the HiPath 3000/5000 Manager E and Assistant T while viewing the status of a board. |
| |
Locking out and releasing boards and ports |
| Using the HiPath 3000/5000 Manager E and Assistant T, you can lock out a complete station or trunk module. The lockout prevents renewed seizure after the current connection has finished. Release or lock out settings are retained after a reset. |
| The first SLMO/SLU board can be blocked. This action does not block the first two ports. You can block specific ports with the "Block selection" option. |
| Ports of an IVM or HG 1500 board cannot be locked. |
| When attempting to lock out the last active trunk, you are subsequently notified that remote service through the service center is no longer possible. |