12.3.2  

Effects of Hardware Changes on Customer Data 
 
Any changes to the hardware must be made before creating a copy of the customer database using HiPath 3000/5000 Manager E. You must ensure that the hardware configuration on the MMC of HiPath 3000 is always current.
Hardware changes include:
 •   removing or inserting boards (HiPath 3000 only).
 •   removing or inserting telephones.
 •   removing or inserting add-on devices or adapters.

12.3.2.1  

Inserting and Removing HiPath 3000 Boards 
Caution  
When using HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300, disconnect the system from the power supply before removing or inserting boards.
Only HiPath 3800 peripheral boards can be removed or inserted during operation.  

Startup Rules for Inserting and Removing Boards  

 Table 12-1   Startup Rules for Inserting and Removing Boards
 If  
 Then  
 Inserting new board in free slot  
The board is integrated into the system according to the rules for initial startup (see Chapter 4 "Installing HiPath 3000").  
 •   System with default numbering plan
The station numbers from the new board are appended (consecutively and in ascending order) to the numbers already assigned.
 •   System with modified numbering plan
The station numbers on the new board can be in any order.
Using HiPath 3000/5000 Manager E or Assistant T, you can assign a specific station to a port. If the number is already assigned to a different object, you can switch both numbers.  
 Replacing board with same or underequipped board type  
Board is activated. The same station range is used.  
 Replacing board with over-equipped board of same type  
Board is activated. The old station range is activated and the ports associated with the new board are inserted at the end. The ports are split if there is no contiguous station range available.  
In the case of subscriber line modules, you can use HiPath 3000/5000 Manager E to retain the old station data by copying it to the new board, or you can delete it and reset the default state. Copying is not possible for trunk boards.  
 Replacing with a different board type  
The system does not automatically activate the board.  
After removing the old board, you can delete it from the database using HiPath 3000/5000 Manager E or Assistant T.
After you have inserted the new board, the system activates it as if it had been inserted into a free slot. However, the CDB area used by the old board is left as a gap.
In the case of subscriber line modules, you can use HiPath 3000/5000 Manager E to retain the old station data by copying it to the new board, or you can delete it and reset the default state. Copying is not possible for trunk boards.  
If you initiate a system reload on a system updated as described above, the system must be reset after the updated CDB has been installed. The reset synchronizes the port placement sequence in the system with that of the CDB.  

Procedure: Exchanging boards  

 Step  
 Activity  
 1.  
Disconnect system from power supply.  
 2.  
Remove the board(s).  
 3.  
Restart the system by plugging in the power plug.  
 4.  
Delete board slot using user interface (29-4).  
 5.  
Disconnect system from power supply.  
 6.  
Insert new board(s).  
 7.  
Restart the system by plugging in the power plug.  
 8.  
Load customer data from the system.  
Adapt customer data to new hardware configuration. Insert new board(s), (stations, for example).  
 9.  
Load new customer data into the system.  

12.3.2.2  

Exchanging Workpoint Clients 
You can add or remove workpoint clients while the system is in operation. The data in the removed workpoint clients is retained.
In case of different telephone models, meaning ones that have a different number of programmable keys, the keypad layout of the previous model is retained. Add-on devices that are not plugged in retain their technical features. With the HiPath 3000/5000 Manager E, you can delete the add-on devices that are not plugged in and remove the keys that are no longer available.