4.1.7 |
Using an External Main Distribution Frame or External Patch Panel |
| The HiPath 3800 has various connection options for connecting the peripherals. The type of connection used will be decided in consultation with the customer on conclusion of the agreement. This may involve the implementation of an external main distribution frame or an external patch panel. |
| This section contains information on the following external components: |
| • | Main distribution frame MDFU-E, Section 4.1.7.1 "Using an External Main Distribution Frame MDFU-E S30805-U5283-X" |
| • | Patch panel S30807-K6143-X, Section 4.1.7.2 "Inserting the External Patch Panel S30807K6143-X" |
| • | S0 patch panel C39104-Z7001-B3, Section 4.1.7.3 "Inserting External S0 Patch Panel C39104-Z7001-B3" |
| • | For U.S. only: Connecting Network Facilities, Section 4.1.7.4 "For U.S. only: Connecting Network Facilities" |
4.1.7.1 |
Using an External Main Distribution Frame MDFU-E S30805-U5283-X |
For U.S. only: |
| No more than 21 CABLUs per MDFU-E with one 16-TW strip or 25-TW strip (9 x 30 mm) can be implemented. |
4.1.7.1.1 |
Mounting the Main Distribution Frame (MDFU-E) |
| The MDFU-E main distribution frame should be installed in the direct vicinity of the system (note length of connection cable) and at eye level. |
| The packing material contains a drawing that can be used as a drilling template. |
Procedure for wall mounting |
| |
4.1.7.1.2 |
Laying the Line Network and Jumpers on the MDFU-E |
Jumpers, external line network |
| Most main distribution frames do not have an external side. You must jumper them to the incoming line network (see jumpering duct, Figure 4-36). Use a standard wiring tool for laying the cable wires. |
Surge protector |
| To divert surge voltage caused by lightning, insert surge protectors on: |
| • | lines that leave the system buildings (outside stations) |
| • | lines > 500 m long |
| Connect the polarized surge protectors to the plugging locations on the splitting strip described above (see Figure 4-38). |
Splitting and jumper strips |
Stripping an open-end cable for the MDFU-E |
Color Codes for the Open-End Cable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4.1.7.2 |
Inserting the External Patch Panel S30807K6143-X |
Structure |
|
4.1.7.2.1 |
Installing the Patch Panel in a 19-Inch Cabinet |
Installation Procedure |
|
| Insert the patch panel (A, in Figure 4-40) above the system cabinet and secure it to the 19-inch frame on both the left and the right using two screws on each side. |
4.1.7.2.2 |
Connecting the Line Network to the External Patch Panel |
|
| Telephones and trunks are connected directly to the MW8 jack on the front of the patch panel. Information on MW8 jack assignment on the front of the patch panel is provided in the board descriptions (in the "Cable and Connector Assignment" table) in Chapter 3 "Boards for HiPath 3000". |
Surge protector |
| To divert surges caused by lightning, insert surge protectors on |
| • | lines that leave the system buildings (outside stations) |
| • | lines > 500 m long. |
| Connect the polarized surge protectors to the plugging locations F1 to F8 provided on the patch panel (see Figure 4-42). |
4.1.7.3 |
Inserting External S0 Patch Panel C39104-Z7001-B3 |
Structure |
|
4.1.7.3.1 |
Installing the S 0 Patch Panel in the 19-Inch Cabinet |
Installation Procedure |
|
| Insert the S0 patch panel (A, in Figure 4-44) above a system cabinet and secure it to the 19-inch frame on both the left and the right using two screws (B) on each side. |
4.1.7.3.2 |
Connecting Lines to the External S0 Patch Panel |
| CABLUs must be manually connected to the S0 patch panel (Figure 4-46). You can use the Krone wiring tool for this. |
Stripping the open-end cable for the S0 patch panel |
| The color codes for open-end cables are provided in Table 4-8. |
4.1.7.4 |
For U.S. only: Connecting Network Facilities |
|
Connecting to the Point of Demarcation |
| Most main distribution frames are designed with a network demarcation block. You must cross-connect the MDF to the incoming trunks. Use a standard wiring tool for laying the cable wires. |
Connecting to T1, PRI, or CorNet |
|
Additional primary protection |
|