| This section contains information on how to install HiPath 3550 and HiPath 3350. This chapter describes the standard installation procedures for the basic system. Refer to Chapter 9 "Expanding and Upgrading HiPath 3000" for information about supplementary equipment and expansions. |
4.2.3.1 |
Selecting the Installation Site |
Selecting a site |
| The customer usually has a preferred installation site in mind. |
| Make sure that the customer's site meets the following guidelines: |
| • | To guarantee sufficient system ventilation, keep the area surrounding the housing clear as follows: allow 30 cm clearance on the left (for board replacement), and 10 cm clearance on the right, top and bottom of the housing. |
| • | Do not expose the systems to direct sources of heat (for example sunlight and heaters). |
| • | Do not expose the systems to extremely dusty environments. |
| • | Avoid contact with chemicals. |
| • | Take every precaution to prevent the formation of condensation on the system during operation. Systems covered with condensation must be dried before being used. |
| • | Observe the environmental conditions specified in Section 2.11 "Environmental Conditions". |
| • | Ensure that the installation site is in the immediate vicinity of an electrical outlet |
| • | Allow space for a main distribution frame or other additional equipment. |
| • | Install lightning and surge arrester equipment. |
| • | Avoid standard carpeting, as it tends to produce electrostatic charges. |
| • | Ensure that a distance of at least 40 in. (101.6 cm) is left between Unify GmbH & Co. KG equipment and other electrical equipment. The National Electrical Code (NEC) requires 36 in. (91.44 cm) of clearance in front of electrical equipment and 40 in. (101.6 cm) of clearance from other electrical service equipment. |
| • | Ensure that the equipment room for the system provides adequate space for installation and maintenance activities, including removing and replacing the cover). Figure 4-48 See for space requirements on the sides of the system. We recommend using a plywood backboard at least 0.5 in. (127 mm) thick and measuring at least 4 ft. (122 cm) by 4 ft. (122 cm.). |
| Information on the design can be found in the following sections: |
| • | HiPath 3550 Section 2.1.4.2 "Design and Dimensions of HiPath 3550" |
| • | HiPath 3350 Section 2.1.4.3 "Design and Dimensions of HiPath 3350" |
4.2.3.1.1 |
For U.S. only: Power plug |
| The AC connection must fulfill the requirements specified in Table 4-11. |
| |
AC Outlet Requirements |
| • | The power source may not be more than 2 m (6 ft.) from the system. |
| • | The power source must supply a voltage of 120 V AC (single phase, fused) in 50-60 Hz. |
| • | A warning should be attached to the circuit breaker to prevent accidental removal of power. |
| • | An independent electric circuit with an isolated ground conductor should be used. |
| • | Recommendation: Add a power surge protector between the AC outlet and the system. |
4.2.3.2 |
Unpacking the Components |
Procedure |
| |
|
4.2.3.3 |
Not for U.S.: Mounting the Main Distribution Frame (HiPath 3550 only) |
Introduction |
| MDFU is the main distribution frame used (see Figure 4-49). |
Installation notes |
| The MDFU-E main distribution frame should be installed in the direct vicinity of the system (note length of connection cable) and at eye level. Mount it on the wall according to the instructions that came with it. The bag attached to the cover contains a drill template. It also contains the necessary screws and wall anchors for attaching the MDF to the wall. |
| The MDFU must be grounded. Refer to Section 4.2.3.6 "Grounding the System and the Main Distribution Frame" for an explanation of the procedure. |
Procedure for mounting the MDFU on the wall |
| |
Layout and dimensions of the MDFU |
4.2.3.4 |
Removing the System Housing Cover |
|
Procedure |
Mounting the housing cover |
| To close the system housing again, put the cover on and fasten it with the two screwed plugs. To avoid injuries, grasp the housing cover by its outside walls only when mounting it. |
4.2.3.5 |
Attaching the System to the Wall |
| Attach the system to the wall as shown in Figure 4-50. |
Attaching the HiPath 3550 and HiPath 3350 housing to the wall |
4.2.3.6 |
Grounding the System and the Main Distribution Frame |
| Implementation guidelines in accordance with IEC 60364 and IEC 60950-1 must be adhered to during installation. |
|
Grounding of the System |
|
USA and Canada: Design of the separate ground conductor |
| The connector cables of systems HiPath 3550 and HiPath 3350 have a ground conductor. The system must also be grounded by a separate ground conductor. This grounding connection must meet the requirements of the relevant authorities (U.S. National Electrical Code, Canadian Electrical Code). Lay a separate grounding from the earth to the system's grounding connector. The cross-section of the grounding must measure at least 14 AWG. |
Grounding for the external main distribution frame |
| The system ground and that of the external MDF must be set from the building's potential equalization bus in a star configuration. |
| • | Not for U.S.: |
| - | HiPath 3550: Shipments always include an MDFU (Germany only) and two grounding cables. Use one of the cables to ground the MDFU. It is not necessary to ground the connection between the MDFU and HiPath 3550 (see Figure 4-52). |
| - | HiPath 3350: This system type does not require an external main distribution frame. The connection cables to the peripherals are attached directly to the boards and routed to the outside via a cable duct inside the housing. |
|
| Refer to Figure 4-52 when replacing a customer system but maintaining the existing external main distribution frame. |
| • | For U.S. only: |
| The customer supplies a main distribution frame to complete the communications system. Mount and ground the MDF in accordance with the manufacturer's instructions. |
Grounding an external main distribution frame |
4.2.3.7 |
Installing the Boards |
| Outside the U.S., the system is already equipped with the boards needed for the customer-specific requirements when the system is delivered. |
| In the U.S., you may need to install the boards. |
Connecting to T1, PRI, or CorNet (for U.S. only) |
|
4.2.3.8 |
Laying the Line Network and Connection Cables |
HiPath 3550 and HiPath 3350 - CABLU for connection to the external main distribution frame |
HiPath 3550 - MDFU connections for peripheral board |
Not for U.S.: HiPath 3550: Connecting the Cabling |
|
Not for U.S.: HiPath 3350: Connecting the Cabling |
| The integrated distribution frame in HiPath 3350 allows you to connect the cable network to the trunk and the stations using screw connections on slip-on connectors. The slip-on connectors (C39334-Z7089-C13) can be easily removed for easy system connection and disconnection. |
| The peripheral boards and optional boards contain a distribution frame component in the form of edge connectors on the boards. The slip-on connectors for these edge connectors are supplied with the boards. |
| If you have an external main distribution frame (MDFU), use CABLU S30269-Z41-A30 (Figure 4-53) to connect the peripheral boards to the customer's line network. As shown in Figure 4-55, you can connect the 8-pin slip-on connectors directly to the boards. The line network connects directly to the jumper strip. |
For U.S. only: HiPath 3550 and HiPath 3350: Connecting the Cabling |
| If the boards are not already connected to the appropriate cables leaving the system, you need to connect them. |
| • | The TST1 Module (HiPath 3550) connects to a customer-supplied channel service unit (CSU) using the supplied cable. The CSU offers the required additional primary protection. |
| • | Each port on the STLS4 Module connects to an S0 bus using the supplied, silver-satin connector cord and a surface-mounted RJ21X jack. The surface-mounted RJ21X jack is not supplied. |
| The signals must be reversed in the RJ45X jack. See Figure 3-70. |
| • | The board in Slot 10 of HiPath 3550 connects using a special cable from the backplane to the main distribution frame (MDF). |
| • | The remaining peripheral boards and options are connected by means of a main distribution frame provided on the customer side or a comparable unit. This is where the MDF cables supplied are used (Octopus cable with Amphenol terminators). You select the output pattern on the Amphenol connector by which slip-on connector you use on each board edge connector. |
| • | Note: The MDF cable reverses the signals coming from the board. This means that R/T on the board interface becomes T/R on the Amphenol connector. |
HiPath 3550 and HiPath 3350: connecting the LAN cable for HXGS3 |
| LAN cables are connected to HXGS3boards in a HiPath 3550 or HiPath 3350 according to the description in Section 3.3.4 "HXGS3, HXGR3". |
| • | Electromagnetic shielding |
| To ensure sufficient electromagnetic shielding (according to EN 55022), a shielded LAN cable must be used, or the LAN cable being used must already be shielded. |
| • | Procedure: LAN cable shield contacts |
|
4.2.3.9 |
Attaching Ferrite |
| To keep within the interference limit required by EMC Class B, you must attach ferrite to the following lines. |
HiPath 3550 and HiPath 3350 power cables (wall housing) |
| The wall housing's power cable must be guided through the C39022-Z7000-C7 ferrite sleeve that is included in the accessory pack. Position the ferrite sleeve as shown in Figure 4-56 so that you will be able to close the housing cover. |
Digital and analog trunk and subscriber lines of the HiPath 3550 and HiPath 3350 (wall housing) |
|
|
4.2.3.10 |
Configuration Notes |
|
HiPath 3550: system overview and slots |
HiPath 3350: system overview and slots |
Static Traffic Capacity |
| The HiPath 3550 and HiPath 3350 systems have the following static traffic capacities. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4.2.3.11 |
Connecting Workpoint Clients |
| For information, see Chapter 10 "Workpoint Clients". |
4.2.3.12 |
Making Trunk Connections |
| Refer to the following board descriptions for information: |
| • | STLS2 (not for U.S.), STLS4 (S0 trunk connection) |
| • | TS2N, HiPath 3550 only (S2M trunk connection) |
| • | TLA2 (Not for U.S.), TLA4 (Not for U.S.), TLA8 (not for U.S.) (MSI) |
| • | TMAMF (for selected countries only), HiPath 3550 only |
| • | TMGL4 (for U.S. only) |
| • | TMQ4 (for U.S. only) |
| • | TST1 (for U.S. only), HiPath 3550 only |
4.2.3.13 |
Performing a Visual Inspection |
| Before starting up the system, you must perform a visual inspection of the hardware, cables, and the power supply. The visual inspection must be performed while the system is disconnected from the power supply. |
|
| |
|