3.3.47 |
4SLA (not for U.S.), 8SLA, 16SLA (Not for U.S.) |
|
Introduction |
| The 4SLA, 8SLA, and 16SLA (Subscriber Line Analog) modules for analog T/R interfaces connect HiPath 3550 and HiPath 3350 (wall housing) to conventional analog telephones and supplementary equipment (such as group 3 fax machines and entrance telephone adapters). |
Interfaces |
| |
| The operating mode (short or long line with the appropriate flash times) can be set up for each subscriber line interface with HiPath 3000/5000 Manager E (the menu settings: Set up station -> Station -> Param -> Flags). |
Technical connection conditions |
| • | Maximum supply current: approximately 34 mA; maximum supply voltage: approximately 40 V DC |
| • | Ring voltage against negative supply voltage (a-wire (tip)/RING): two telephones maximum |
| • | Range, see Section 2.7 "Interface-to-Interface Ranges" |
| • | Loop current detection > 10 mA |
| • | Ground button detection > 20 mA |
| • | The transmission technology is set according to the specific country through the respectively entered country code (for country initialization, see Chapter 5 "Starting Up HiPath 3000"). |
| HiPath 3000/5000 V9, Service Documentation, Issue 10 | up ![]() |
|
![]() |
||