3.2.1 |
CBCC |
|
Octopus F100 |
| Except for the CBCC board, the Octopus F100 communication system is identical in structure to HiPath 3350. The part number of this CBCC is: S30810-K2935-T401. |
Introduction |
| The CBCC board (Central Board with Coldfire Com) performs all central control and attendant functions for HiPath 3550 and HiPath 3350. |
| This description refers to the following versions of central CBCC board: |
| • | CBCC S30810-Q2935-A401: Implemented from V6.0 Rel. 10 or later and V5.0 Rel. 15 or later. Essential new functions: |
| - | Integration of the functionality of the LIM subboard |
| - | Increase of the ring voltage of analog station interfaces (T/R) to approx. 65 Veff |
| - | Discontinuation of the second V.24 interface (Option V24/1) |
| • | CBCC S30810-Q2935-A301: implemented in V5.0 or later Essential new function: CLIP |
| Differences between both CBCC versions are indicated at the appropriate point in the following description. |
Subboards |
| The following subboards can be used depending on the application: |
| • | Clock module CMA or CMS (optional) |
| • | MMC multimedia card |
| • | IMODN integrated modem card new (optional) |
| • | Music on hold (optional): |
| - | MPPI (Product of BEYERTONE GmbH) |
| - | MUSIC (Product of Sound Player GmbH) |
| - | EXM |
| • | Entry Voice Mail EVM (optional): Pluggable up to HiPath 3000/5000 V7, securely soldered as of HiPath 3000/5000 V8. |
| • | LAN Interface Module LIM (optional, for CBCC S30810-Q2935-A301 only) |
Outputs, interfaces |
| • | Ethernet (10 BaseT)/10 MBit) LAN interface, only in CBCC S30810-Q2935-A401 The interface can, for example, be used for the following applications: |
| - | For administration using HiPath 3000 Manager E |
| - | For the TAPI 120/170 connection via the CSTA interface. Bear in mind, however, that the number of BHCAs (Busy Hour Call Attempts = number of connection attempts during busy traffic hours) is restricted to 400 at a maximum of six CSTA links for the TAPI 120/170 connection. The use of "power dialers" is not approved. |
| - | For the output of call data |
| The ETHERNET-LAN interface is deactivated by the system software deactivated as soon as an HG 1500 board is inserted. |
| • | Eight digital UP0/E subscriber lines For example, UP0/E workpoint clients or BS3/1 base stations for HiPath Cordless Office can be connected here. |
| • | Four analog T/R subscriber lines For U.S. only: These interfaces do not support the connection of external extensions via OPS (Off-Premises Station) signaling. CBCC S30810-Q2935-A401: The interfaces supply a ring voltage of approx. 65 Veff. CBCC S30810-Q2935-A301: The T/R interfaces supply a ring voltage of approx. 35 Veff. Depending on the terminals connected, we cannot exclude the possibility of errors occurring during ringing state. |
| • | Two digital S0 interfaces (CO (default) or station) |
| • | Backplane (CUC or CUP) connection via slots 1 (X11), 2 (X5) and 3 (X6) |
| • | Music on Hold: MPPI, MUSIC or EXM |
|
| • | Options bus (O bus) |
| • | V.24 interface CBCC S30810-Q2935-A301: A second V.24 interface can be realized via the V24/1 option. |
Switches and indicators |
| • | Reset/reload switch |
| - | Switch pressed < 5 s = Reset activated |
| - | Switch pressed > 5 s = Reload activated (RUN LED out indicates that a reload is in progress) |
| • | Run LED LED status meaning is explained in the following table. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure CBCC S30810-Q2935-A401 |
Figure CBCC S30810-Q2935-A301 |
|
X1 to X4 contact assignments |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
S0 interface assignment |
| |
V.24 interface assignment |
| |
LAN connector assignment |
| CBCC S30810-Q2935-A301: The Ethernet LAN interface is provided by the optional LIM subboard. |
| |
Default numbering plan when using CBCC in HiPath 3550 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Default numbering plan when using CBCC in HiPath 3350 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HiPath 3000/5000 V9, Service Documentation, Issue 10 | up ![]() |
|
![]() |
||
| Disclaimer & Copyright | ID: P31003H3590S100017620 | 2014-02-27 |