3.3.14  

SLCN (not for U.S.) 
 
NOTE  
Danger of damage to property due to surge voltage. The required lightning protection measures must be taken for this board, see Section 2.1.2 "Lightning Protection".  

Introduction  
The SLCN (Subscriber Line Module Cordless New) board is used in HiPath 3800 and connects base stations to HiPath Cordless Office. There are 16 UP0/E ports available for this.
You can install up to four SLCN boards in one system.
Chapter 11 "HiPath Cordless Office" contains basic information on the options available for operating HiPath Cordless Office.
Base stations must be clocked with a high degree of accuracy for HiPath Cordless Office. For this, the subboard CMS must be plugged into the CBSAP board (see Table 11-1).

Front panel  
 Figure 3-58   SLCN (not for U.S.) (S30810-Q2193-X300) - LEDs in the Front Panel
 
An additional shielding panel is not required on the front side of this board, because the EMC shield is already provided by the front panel.

LED statuses and their meanings  

 Table 3-64   SLCN (not for U.S.) - LED Statuses
 Red LED  
 Green LED  
 Status  
 Action  
 Off  
 Off  
Board not receiving power or not plugged in correctly.  
Board is out of order.  
Check plug contact on board.  
 On  
 Off  
Board is receiving power and board test is in progress.  
Board is defective if status remains unchanged (board test unsuccessful).  
 
 
Replace board.  
Loadware loading not successfully completed. Board is faulty.  
Replace board.  
Error detected on board.  
Board is deactivated (not applicable to errors detected by test loops) or board was deactivated using HiPath 3000/5000 Manager E.  
Check whether the board was deactivated using HiPath 3000/5000 Manager E. If not, replace board.  
 Flashing  
 Off  
Loadware is being loaded.  
 
 Off  
 On  
Board test completed successfully. Board is OK (idle state).  
 
 Off  
 Flashing  
At least one subscriber line circuit is activated.  
 

Cable and connector assignment  
 •   For connecting to the SIVAPAC connector on the backplane: Table 3-65
 •   For connecting to the connector panels using RJ45 jacks: Table 3-66
 •   For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-67

 Table 3-65   SLCN (not for U.S.) - SIVAPAC Connector Assignment on the Backplane
 Pair  
 a-wire (tip)1  
 b-wire (ring)1  
 SIVAPAC connector  
 SLCN  
 MDFU-E  
 Notes  
 1  
 wht/blu  
   
 1  
 1a  
 Port 1  
 1a  
   
   
 blu/wht  
 23  
 1b  
 1b  
 2  
 wht/ora  
   
 3  
 2a  
 Port 2  
 2a  
   
   
 ora/wht  
 4  
 2b  
 2b  
 3  
 wht/grn  
   
 5  
 3a  
 Port 3  
 3a  
   
   
 grn/wht  
 6  
 3b  
 3b  
 4  
 wht/brn  
   
 7  
 4a  
 Port 4  
 4a  
   
   
 brn/wht  
 8  
 4b  
 4b  
 5  
 wht/gry  
   
 9  
 5a  
 Port 5  
 5a  
   
   
 gry/wht  
 10  
 5b  
 5b  
 6  
 red/blu  
   
 11  
 6a  
 Port 6  
 6a  
   
   
 blu/red  
 12  
 6b  
 6b  
 7  
 red/ora  
   
 13  
 7a  
 Port 7  
 7a  
   
   
 ora/red  
 14  
 7b  
 7b  
 8  
 red/grn  
   
 15  
 8a  
 Port 8  
 8a  
   
   
 grn/red  
 16  
 8b  
 8b  
 9  
 red/brn  
   
 17  
 9a  
 Port 9  
 9a  
   
   
 brn/red  
 18  
 9b  
 9b  
 10  
 red/gry  
   
 19  
 10a  
 Port 10  
 10a  
   
   
 gry/red  
 20  
 10b  
 10b  
 11  
 blk/blu  
   
 24  
 11a  
 Port 11  
 11a  
   
   
 blu/blk  
 25  
 11b  
 11b  
 12  
 blk/ora  
   
 26  
 12a  
 Port 12  
 12a  
   
   
 ora/blk  
 27  
 12b  
 12b  
 13  
 blk/grn  
   
 29  
 13a  
 Port 13  
 13a  
   
   
 grn/blk  
 30  
 13b  
 13b  
 14  
 blk/brn  
   
 31  
 14a  
 Port 14  
 14a  
   
   
 brn/blk  
 32  
 14b  
 14b  
 15  
 blk/gry  
   
 34  
 15a  
 Port 15  
 15a  
   
   
 gry/blk  
 35  
 15b  
 15b  
 16  
 yel/blu  
   
 37  
 16a  
 Port 16  
 16a  
   
   
 blu/yel  
 38  
 16b  
 16b  
1see "Abbreviations for colors" at the start of Section 3.3 "Peripheral boards".

 Table 3-66   SLCN (not for U.S.) - Assignment of Connector Panels with RJ45 Jacks
 RJ45 jack  
 SLCN  
 Notes  
 No.  
 Pin  
 1  
 4  
 1a  
   
 5  
 1b  
 2  
 4  
 2a  
   
 5  
 2b  
 3  
 4  
 3a  
   
 5  
 3b  
 4  
 4  
 4a  
   
 5  
 4b  
 5  
 4  
 5a  
   
 5  
 5b  
 6  
 4  
 6a  
   
 5  
 6b  
 7  
 4  
 7a  
   
 5  
 7b  
 8  
 4  
 8a  
   
 5  
 8b  
 9  
 4  
 9a  
   
 5  
 9b  
 10  
 4  
 10a  
   
 5  
 10b  
 11  
 4  
 11a  
   
 5  
 11b  
 12  
 4  
 12a  
   
 5  
 12b  
 13  
 4  
 13a  
   
 5  
 13b  
 14  
 4  
 14a  
   
 5  
 14b  
 15  
 4  
 15a  
   
 5  
 15b  
 16  
 4  
 16a  
   
 5  
 16b  
 17  
 4  
   
 Free  
 5  
   
 18  
 4  
   
 Free  
 5  
   
 19  
 4  
   
 Free  
 5  
   
 20  
 4  
   
 Free  
 5  
   
 21  
 4  
   
 Free  
 5  
   
 22  
 4  
   
 Free  
 5  
   
 23  
 4  
   
 Free  
 5  
   
 24  
 4  
   
 Free  
 5  
   

 Table 3-67   SLCN (not for U.S.) - Assignment of Connector Panels with SIPAC 1 SU Connectors (Cable for Ports 1 - 16)
 Color Group  
 Pair  
 a-wire (tip)1  
 b-wire (ring)1  
 SU connector  
 SLCN  
 MDFU-E  
 Patch Panel,
MW8 pin
 
 Notes  
 1  
 1  
 wht/blu  
   
 19  
 1a  
 Port 1  
 1a  
 4  
   
   
 blu/wht  
 39  
 1b  
 1b  
 5  
 2  
 wht/ora  
   
 38  
 2a  
 Port 2  
 2a  
 4  
   
   
 ora/wht  
 48  
 2b  
 2b  
 5  
 3  
 wht/grn  
   
 27  
 3a  
 Port 3  
 3a  
 4  
   
   
 grn/wht  
 47  
 3b  
 3b  
 5  
 4  
 wht/brn  
   
 16  
 4a  
 Port 4  
 4a  
 4  
   
   
 brn/wht  
 46  
 4b  
 4b  
 5  
 5  
 wht/gry  
   
 05  
 5a  
 Port 5  
 5a  
 4  
   
   
 gry/wht  
 45  
 5b  
 5b  
 5  
 2  
 6  
 red/blu  
   
 14  
 6a  
 Port 6  
 6a  
 4  
   
   
 blu/red  
 44  
 6b  
 6b  
 5  
 7  
 red/ora  
   
 23  
 7a  
 Port 7  
 7a  
 4  
   
   
 ora/red  
 43  
 7b  
 7b  
 5  
 8  
 red/grn  
   
 32  
 8a  
 Port 8  
 8a  
 4  
   
   
 grn/red  
 42  
 8b  
 8b  
 5  
 9  
 red/brn  
   
 11  
 9a  
 Port 9  
 9a  
 4  
   
   
 brn/red  
 31  
 9b  
 9b  
 5  
 10  
 red/gry  
   
 02  
 10a  
 Port 10  
 10a  
 4  
   
   
 gry/red  
 22  
 10b  
 10b  
 5  
 3  
 11  
 blk/blu  
   
 13  
 11a  
 Port 11  
 11a  
 4  
   
   
 blu/blk  
 33  
 11b  
 11b  
 5  
 12  
 blk/ora  
   
 04  
 12a  
 Port 12  
 12a  
 4  
   
   
 ora/blk  
 24  
 12b  
 12b  
 5  
 13  
 blk/grn  
   
 15  
 13a  
 Port 13  
 13a  
 4  
   
   
 grn/blk  
 35  
 13b  
 13b  
 5  
 14  
 blk/brn  
   
 06  
 14a  
 Port 14  
 14a  
 4  
   
   
 brn/blk  
 26  
 14b  
 14b  
 5  
 15  
 blk/gry  
   
 17  
 15a  
 Port 15  
 15a  
 4  
   
   
 gry/blk  
 37  
 15b  
 15b  
 5  
 4  
 16  
 yel/blu  
   
 08  
 16a  
 Port 16  
 16a  
 4  
   
   
 blu/yel  
 28  
 16b  
 16b  
 5  
1see "Abbreviations for colors" at the start of Section 3.3 "Peripheral boards".

System Configuration Using SLCN  
For information on the maximum possible system configuration of HiPath Cordless Office with the SLCN boards see Table 11-1.

SLCN board distribution in HiPath 3800 cabinets  
You can install up to four SLCN boards in HiPath 3800. A system cabinet can be fitted with all four SLCN boards.
To guarantee uninterrupted operation of the HiPath 3800, not more than two SLCN boards should be plugged in to a PCM segment. This condition must always be observed. For information on PCM segment distribution, see Section 4.1.5.7 "Distribution of the PCM Highway".  
One board slot should be kept free between two SCLN boards to prevent overheating.  

Supplying power to base stations  
Power is supplied to the base stations primarily via the internal PSU in the system in question.
If the correct number of LUNA2 modules was calculated, the system's internal power supply unit provides sufficient power to supply the HiPath Cordless Office system configuration specified in Table 11-1.