3.3.8  

IVMS8, IVMS8R 
 

Introduction  
The following boards are used for the integrated voice mail functionality in HiPath Xpressions Compact in V1.2 and later:
 •   IVMS8 (Integrated Voice Mail Small) S30122-Q7379-X - for HiPath 3550 and HiPath 3350 (wall housing)
 •   IVMS8R (Integrated Voice Mail Small Rack) S30122-K7379-Z - for HiPath 3500 and HiPath 3300 (19-inch housing)
Music on Hold can be used in V4.0 SMR-7 or later and announcements in V5.0 or later.
In addition, the boards have an Ethernet (10/100BaseT) interface which can be used for HiPath Xpressions Compact administration (fast APS transfer, backup and restore activities).
Only one IVMS8 or IVMS8R may be installed per system.  
For thermal reasons, the IVMS8 board may only be used in slots 5, 7 and 9 (lower slots) in the HiPath 3550 (wall housing).  
Slot 5 can only be used for the IVMS8 board in the HiPath 3350 (wall housing).  
For detailed information on HiPath Xpressions Compact, startup and administration, see the manual for the product.
HiPath Xpressions Compact supports a central voice mail functionality in a HiPath 3000/5000 network. All stations can use the central voice mail server.  
HiPath Xpressions Compact may be used as a central announcement device in a network system with V6.0 SMR-06 or later.  

Packing protection covering  
You must remove the red packing protection covering (cardboard block), shown in the following picture, before starting up the board.
If it is necessary to transport the board again at a later time, for example, for servicing, you must reattach the packing protection covering.
 Figure 3-43   IVMS8, IVMS8R - Packing Protection Covering
 

Switches and LEDs  
 Figure 3-44   IVMS8, IVMS8R (S30122-Q7379-X, -K7379-Z)
 

Lockout switch settings  
 •   Pressed = free (default)
 •   Not pressed = locked: existing connections remain active, new connections are locked.
   -   The yellow LED lights up when all connections are ended and the board is effectively locked.
   -   The yellow LED flashes when a lockout request is entered (via lockout switch or software) but at least one call is still active.
To reset the board to the default state, activate the lockout switch twice within the first 10 s of board startup.

Front view of IVMS8R  
 Figure 3-45   IVMS8R - Front View (S30122-K7379-Z)
 

Assignment of the RJ45 jack X3  
The Ethernet (10/100BaseT) interface is accessed via the 8-pin RJ45 jack X3. The signals are output simultaneously at the printed circuit connector X2.

 Table 3-48   IVMS8, IVMS8R - Assignment of the RJ45 Jack X3 (LAN Connector)
 RJ45 Jack X3  
 Pin  
 Signal  
 Description  
 Printed Circuit Connector X2  
 Pin  
 1  
 Tx +  
Transmit +  
 1  
 2  
 Tx -  
Transmit -  
 3  
 3  
 Rx +  
Receive +  
 7  
 4  
 -  
Not used  
   
 5  
 -  
Not used  
   
 6  
 Rx -  
Receive -  
 9  
 7  
 -  
Not used  
   
 8  
 -  
Not used  
   

LED statuses and their meanings  

 Table 3-49   IVMS8, IVMS8R - LED Statuses
 LED
yellow  
 LED
green  
 Meaning  
 Action  
During Startup and Initialization  
 Off  
 Off  
 1  
Boot procedure (lasts approx. 8 - 12 s)  
 
 On  
 On  
 2  
LED test (lasts approx. 10 s)  
 
 On  
 Off  
 3  
Lockout switch state signaling by yellow LED (lasts approx. 5 s):  
 •   blocked = On
 •   free = Off
Possibly check if board was deactivated using HiPath 3000/5000 Manager E or lockout switch.  
 Off  
 Flashing
(500/500 ms)  
 Off  
 4  
Hard disk test, application startup (depending on hard disk status, lasts approx. 3 - 8 minutes)  
 
 Off  
 On  
 5a  
Standby mode after successful boot  
 
 On  
 Off  
 5b  
Board locked or board error occurred  
Check whether board was deactivated using HiPath 3000/5000 Manager E or lockout switch.  
During Operation  
 Off  
 On  
Idle (no call)  
 
 Off  
 Flashing
(500/500 ms)  
At least one active port (call)  
 
 Flashing
(500/500 ms)  
 Flashing
(500/500 ms)  
Lockout switch activated during a call  
 
 On  
 Off  
Board locked or board error occurred  