3.3.1  

DIU2U (for U.S. only) 
 

Introduction  
The DIU2U (Digital Interface Unit 2 Universal) trunk module connects two digital trunks to HiPath 3800 and in this way provides two primary rate interfaces (PRI) ISDN via T1 interfaces.

Connection types  
 •   Fiber optic cable
The fiber optic cable is only connected via the front panel. The opto-electronic converter AMOM must be used to connect a fiber optic cable to the 15-pin Sub-D jacks on the front panel.
 •   Copper cable
The copper cable is connected to T1-CSU (Customer Service Unit) or DSU (Data Service Unit) via the adapter cable (C39195-A7269-B625) shown in Figure 3-30.

Adapter cable C39195-A7269-B625  
 Figure 3-30   DIU2U (for U.S. only) Adapter Cable C39195-A7269-B625
 

 Table 3-29   DIU2U (for U.S. only) - adapter cable assignment (C39195-A7269-B625)
 15-pin Sub-D connector  
 Pin  
 50-pin Amphenol connector  
 Pin  
 Function  
 Color code  
 9  
 38  
 a-wire (T), transmit  
 wht/blu  
 1  
 13  
 b-wire (R), transmit  
 blu/wht  
 15  
 41  
 a-wire (T), receive  
 wht/ora  
 8  
 16  
 b-wire (R), receive  
 ora/wht  

Front panel  
 Figure 3-31   DIU2U (for U.S. only) - Front Panel (S30810-Q2216-X)
 
An additional shielding panel is not required on the front side of this board, because the EMC shield is already provided by the front panel.

LED statuses and their meanings  

 Table 3-30   DIU2U (for U.S. only) - LED Statuses
 Red LED  
 Green LED  
 Status  
 Action  
 Off  
 Off  
Board not receiving power or not plugged in correctly.  
Board is out of order.  
Check plug contact on board.  
 On  
 Off  
Board is receiving power and board test is in progress.  
Board is defective if status remains unchanged (board test unsuccessful).  
 
 
Replace board.  
Loadware loading not successfully completed. Board is faulty.  
Replace board.  
Error detected on board.  
Board is deactivated (not applicable to errors detected by test loops) or board was deactivated using HiPath 3000/5000 Manager E.  
Check whether the board was deactivated using HiPath 3000/5000 Manager E. If not, replace board.  
 Flashing  
 Off  
Loadware is being loaded.  
 
 Off  
 On  
Board test completed successfully. Board is OK (idle state).  
 
 Off  
 Flashing  
At least one channel is activated.