10.3.2  

Cordless | SLC 
 


Settings | Cordless | SLC
 
The parameters for the SLC16 card can be configured via SLC. All cordless cards are displayed in the system.

10.3.2.1  

Table SLC 

System ID  
If a HiPath 3000 system belongs to a HiPath 5000 RSM networking, its Node ID is greater than zero (Network -> HiPath 5000 RSM/AllServe Parameter -> Node -> Node ID). In this case, the System ID of the SLC board of the HiPath 3000 system (Cordless -> Multi-SLC -> SystemID) must be the same one like the Node ID.  
-  
Slot  
Slots of the inserted SLC16 cards  
-  
SLC16 no.  
Unique system-wide ID number of the SLC card
configurable  
The range of values is: 1-15, 17-31, 33-47, ..., 127 (multiples of 16 are not allowed).  
Number of PPs  
Number of Portable Parts (PP).  
The number of portable parts can be increased in the Portable Parts area  
-  
SLC Call no.  
Unique system-wide call number of the S0 extension line  
configurable  
Access  
Name, number and slot of the S0 extension line  
-  
If a still unconfigured cordless card is detected, the corresponding row in the table is preset with automatically configured data and shaded in gray. In addition, a message appears indicating that this data will only be copied to the CDB on clicking Apply. The predefined values are the SLC16 no. and, for the first cordless card, also the system ID. If the system ID is preset, the node ID is used. If the node ID should be "0" (if the system consists of only one node), the system ID is preset to "1". If cordless cards have already been configured, their system IDs are taken as the defaults. The node ID is used for systems with multiple nodes.

Check  
On clicking the Check button, the SLC16 no. and the SLC call no. are checked for system-wide uniqueness.

10.3.2.2  

Area: Portable Parts (mobile telephones) 
The parameters of the portable parts (PPs or mobile telephones) are displayed in the table.. You can then choose to display either the mobile telephones of the SLC card selected in the table per SLC in Slot) or all mobile telephones (All).

Call Number  
Call no. of the mobile phone  
-  
Name  
Name of the mobile phone  
-  
Mobile code  
PIN code to log on the mobile telephone.  
configurable  
The mobile code must be unique system-wide.  
Access  
Name, number and slot for the S0 extension line  
-  

Status display of the PP  
An icon in front of the mobile code displays the status. The following combinations are possible:

Port active  
PP registered  
Status display  
Meaning  
no  
yes  
green  
OK  
yes  
yes  
red  
Board lockswitch set for registered PP  
no  
no  
yellow  
PP was automatically logged off by a change to the PIN in the Manager E.  
yes  
no  
gray  
No PP was ever registered on this port.  

Add  
If the number of portable parts is less than the (version-dependent) size allowed in the system, then the field next to the Add button can be used to enter and add an additional number of portable parts (per card).

Deleting PPs  
The Portable Parts selected in the table are removed from the system with Delete.

Fill Mobile Code  
The Fill Mobile Code button is used to automatically generate the PIN codes for registering mobile telephones. The PIN for the mobile code is generated from the call number of the station. No mobile code is generated for stations without call numbers; the mobile codes must be entered manually in such cases.

See also:  
   -   Section 10.3.1 "Cordless | System-wide"
   -   Section 10.3.3 "Cordless | Multi-SLC"