9.19.11  

Maintenance | V.24 Status 
 
V.24 Status can be used to query the status of a V.24 interface on the central board or a terminal adapter of a sytem telephone.

9.19.11.1  

Area: Interface selection 
Is used to select the wanted interface. A distinction can be made between a V.24 interface on the central board or a terminal adapter of a system telephone. The V.24 interface can be selected via the V.24 port drop-down list. A terminal adapter can be selected by entering the station number of the sytem telephone, to which the terminal adapter has been connected.

9.19.11.2  

Area: Line status 
After clicking on the Read data button, the states are displayed.
   -   Line status = 1 means "Line active"
   -   Line status = 0 means "Line inactive"
The individual lines are assigned as follows:
   -   DTR: Communication system
   -   DSR: Telephone
   -   RTS: Communication system
   -   CTS: Telephone
Two status examples are given in the following:
Example 1: Port open:
   -   DTR: 1
   -   DSR: 0
   -   RTS: 1
   -   CTS: 0
Example 2: HiPath 3000 Manager Online:
   -   DTR: 1
   -   DSR: 1
   -   RTS: 1
   -   CTS: 1

9.19.11.3  

Area: Monitoring V.24 
The Start and Stop buttons can be used to start or stop monitoring. In case of started monitoring, the incurred time and the number of sent/received bytes is displayed.
After monitoring has been stopped, the transferred bytes can be viewed by activating the buttons Hexadecimal, ASCII or Hex + ASCII. For this purpose, an external text editor (default is Wordpad) is started; this editor can also be used to store or print data. The desired editor can be configured via the File ass_150e.ini.