9.3 |
Relays |
| Implementing features, see also Manager E Relays |
Definition |
| HiPath 3000/5000 provide control outputs (relays) on an optional control relay module. This enables you to perform the following functions from any connected telephone by entering codes: |
| • | Manual switch on and off |
| • | Timer-controlled switch |
| • | Door opener control |
| • | Connection-controlled entrance telephone amplifier |
| • | Door busy indicator for a configurable station |
| • | Night bell |
| • | Secondary bell |
| • | Announcement device start and stop control |
| • | External music on hold (MOH) control |
| • | Second ringer simulation type |
| • | Simulation of call charge pulses |
| • | Station active |
| The optional control relay modules STRB (with HiPath 3550 and HiPath 3350) and STRBR (with HiPath 3500 and HiPath 3300) can be implemented with four control inputs and four outputs each for functions such as monitoring, alarm, control and adjustment. This can be used in security systems or Property Management Systems (PMS). A control relay module can be connected for each system (HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300). The relay card REALS which provides four control outputs is available for HiPath 3800. |
| The signal input function (control input) is triggered by closing any of the external floating contacts. The external electric circuit is supplied by the control relay module and electrically isolated from the system controller by means of an optocoupler. |
| The relays can be controlled via codes from every connected telephone and remotely via the trunk line (DISA) by the station user associated with the relay function or for with the aid of the feature Associated Services. |
| Assigning Functions to the Actuators (Relays) |
| • | No function type |
| The relevant actuator is either not operating or is entered as a common ringer under Call management, Call destination lists. |
| • | Manually on and off type |
| The relay can be activated or deactivated for switching purposes by means of the codes Activate or deactivate selected switch. For key terminals this function can also be programmed on a key. A specific station, a group or all stations can be allocated to this relay type by selecting NONE. For this relay type, shutdown can be delayed if a value greater than 0 is entered in the Switching time field. The switching time is a multiple of 100ms. |
| • | Automatic off after timeout type |
| The relay can be activated or deactivated as a time switch by means of the code Activate selected switch (see above). For key terminals this function can also be programmed on a key. A specific station, a group or all stations can be allocated to this relay type by selecting None. The switching time is a multiple of 100ms. |
| • | Door busy indicator type |
| The relay is activated if the allocated station ceases to be in the idle condition. This means that the handset has been picked up, the loudspeaker is activated or the extension is being called. The relay is deactivated when the allocated station returns to the idle condition. This means that the handset has been replaced, the loudspeaker has been deactivated and the extension is not being called. The relay can also be activated directly by means of the code Activate/deactivate selected switch. For system telephones, this function can also be programmed on a key. If the relay was activated by means of a code or a key, the status of the allocated station is ignored and the relay can only be deactivated again by means of a code or a key. |
| Practical uses: Door busy indicator Do not disturb, Meeting, Conference, PC connection for data transmission (power management). A specific station must be allocated to this relay type. In the case of this relay type, shutdown can be delayed if a value greater than 0 has been entered in the switching time field. The switching time is a multiple of 100ms. |
| • | Second ringer simulation type |
| The relay is activated for the allocated station if it is being called. This relay is deactivated when the called party answers or the call is terminated. This relay is not clocked. A specific station must be allocated to this relay type. In the case of this relay type, shutdown can be delayed if a value greater than 0 has been entered in the switching time field. The switching time is a multiple of 3 seconds. |
| • | Door opening system type |
| See Automatic after timeout type. The text "Door opener" is displayed for the allocated terminals. |
| • | Doorphone amplifier type |
| The relay is activated when connected to the doorphone. The relay is deactivated when disconnected from the doorphone or entrance telephone/loudspeaker. This makes it possible to control a doorphone amplifier so that it is only activated when required. A doorphone or the loudspeaker port must be allocated to this relay type. |
| • | Music on Hold (MOH) |
| The relay is activated if at least one station or a line in the system is not in the idle condition. The relay is deactivated if all stations and lines in the system are in the idle condition. |
| Practical application: Activation of a tape device, CD player, PC connection power management, etc. "None" must be entered as allocated station for this relay type. and it must only occur once in the system. In the case of this relay type, shutdown can be delayed if a value greater than 0 has been entered for the Switching time field. The switching time is a multiple of 100ms. |
| • | Station active |
| The relay is activated if the allocated station is active. This means that the handset has been picked up or the loudspeaker has been activated. The relay is deactivated if the allocated station resumes the idle condition. This means that the handset has been replaced or the loudspeaker has been deactivated. The relay can also be activated directly by means of the code Activate/deactivate selected switch. For system telephones, this function can also be programmed on a key. If the relay was activated by means of a code or a key, the status of the allocated station is ignored and the relay can only be deactivated again by means of a code or a key. A specific station must be allocated to this relay type. In the case of this relay type, shutdown can be delayed if a value greater than 0 has been entered in the Switching time field. The switching time is a multiple of 100ms. |
| Assigning Actuator Names |
| Any names (up to 16 characters) can be assigned to the actuators to be administered. |
Model-Specific Data |
| |
Dependencies/Restrictions |
| |