5.3.19 |
E911 Emergency Call Service for the USA (for U.S. only) |
| Implementing features, see also Manager E Emergency Call Service for the USA |
|
Definition |
| The E911 expanded emergency call service makes it possible to transmit information about the physical location of a station in addition to the station number. Therefore not only the number of the station placing the call is available in the emergency call center, but the location too. |
| This requires that each subscriber line with a valid DID number be assigned a Location Identification Number LIN. The LIN is an unambiguous, max. 12-digit number that corresponds to the 10-digit NANP (North American Numbering Plan). Subscriber lines that are physically close to one another are given the same LIN. The emergency call center has a database that contains all the LINs and that uses the transmitted LIN to identify the name and address of the one placing the emergency call. |
| V1.2 and later of HiPath 3000/5000 supports this feature for analog (loop start protocol) and digital trunks (Primary Rate Interface PRI). |
|
| Figure 5-1 | Expanded Emergency Call Service E911 (for USA only)
|
Model-Specific Data |
| |
Dependencies/Restrictions |
| |
| HiPath 3000/5000 V9, Feature Description, Issue 10 | up ![]() |
|
![]() |
||