10.5.1 |
optiPoint 500 Telephones |
10.5.1.1 |
optiPoint 500 entry |
Main features |
| • | 8 function keys with LEDs (can be modified with HiPath 3000/5000 Manager E; for information on key programming, see Section 10.6 "Key Programming") |
| • | Open listening |
| • | 2 volume adjustment keys (plus/minus) and pitch |
| • | Suitable for wall mounting |
| • | No modularity (no connecting capability for adapters or key modules), no display |
Standard key assignment (default) for optiPoint 500 entry |
| Refer to Section 10.5.1.6 "Connection Requirements for HiPath 3000" for connection requirements. |
10.5.1.2 |
optiPoint 500 economy (not for U.S.) |
Main features |
| • | 12 function keys with LEDs (4 can be modified with HiPath 3000/5000 Manager E, 8 freely programmable; for information on key programming, see Section 10.6 "Key Programming") |
| • | Alphanumeric LCD display (swivel) with 2 lines, 24 characters each |
| • | 3 dialog keys for interactive user prompts: "Yes", "Back", and "Next" |
| • | Open listening |
| • | 2 volume adjustment keys (plus/minus), pitch and display contrast |
| • | Suitable for wall mounting |
| • | No modularity (no connecting capability for adapters or key modules) |
Standard key assignment (default) for optiPoint 500 economy |
| Refer to Section 10.5.1.6 "Connection Requirements for HiPath 3000" for connection requirements. |
10.5.1.3 |
optiPoint 500 basic |
Main features |
| • | 12 function keys with LEDs (4 can be modified with HiPath 3000/5000 Manager E, 8 freely programmable; for information on key programming, see Section 10.6 "Key Programming") |
| • | Alphanumeric LCD display (swivel) with 2 lines, 24 characters each |
| • | 3 dialog keys for interactive user prompts: "Yes", "Back", and "Next" |
| • | Open listening |
| • | 2 volume adjustment keys (plus/minus), pitch and display contrast |
| • | Interfaces and slots: |
| - | 1 USB 1.1 interface |
| - | 1 option bay |
| - | 1 interface for up to 2 add-on devices |
| • | Suitable for wall mounting |
Standard key assignment (default) for optiPoint 500 basic |
| Refer to Section 10.5.1.6 "Connection Requirements for HiPath 3000" for connection requirements. |
10.5.1.4 |
optiPoint 500 standard, optiPoint 500 standard SL (for U.S. only) |
| Note: optiPoint 500 standard and optiPoint 500 standard SL (for U.S. only) function exactly the same on HiPath 3000 systems. |
Main features |
| • | 12 function keys with LEDs (4 can be modified with HiPath 3000/5000 Manager E, 8 freely programmable; for information on key programming, see Section 10.6 "Key Programming") |
| • | Alphanumeric LCD display (swivel) with 2 lines, 24 characters each |
| • | 3 dialog keys for interactive user prompts: "Yes", "Back", and "Next" |
| • | Full-duplex speakerphone mode with echo suppression for room adaptation |
| • | 2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast |
| • | Interfaces and slots: |
| - | 1 integrated USB 1.1 interface |
| - | 1 option bay |
| - | 1 interface for up to 2 add-on devices |
| • | Suitable for wall mounting |
Standard key assignment (default) for optiPoint 500 standard |
| Refer to Section 10.5.1.6 "Connection Requirements for HiPath 3000" for connection requirements. |
10.5.1.5 |
optiPoint 500 advance |
Main features |
| • | 19 function keys with LEDs (4 can be modified with HiPath 3000/5000 Manager E, 15 freely programmable; for information on key programming, see Section 10.6 "Key Programming") |
| • | Alphanumeric LCD display (swivel) with 2 lines, 24 characters each. Background lighting that stays lit for approximately 5 s. |
| • | 3 dialog keys for interactive user prompts: "Yes", "Back", and "Next" |
| • | Full-duplex speakerphone mode with echo suppression for room adaptation |
| • | 2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast |
| • | Interfaces and slots: |
| - | 1 integrated USB 1.1 interface |
| - | 2 option bays |
| - | 1 interface for up to 2 add-on devices |
| - | 1 headset port (121 TR9-5) |
| • | Suitable for wall mounting |
Standard key assignment (default) for optiPoint 500 advance |
| Refer to Section 10.5.1.6 "Connection Requirements for HiPath 3000" for connection requirements. |
10.5.1.6 |
Connection Requirements for HiPath 3000 |
Hardware requirements |
| |
Connecting as a client telephone |
|
10.5.1.7 |
Connection |
Procedure: Connecting an optiPoint 500 Telephone |
|
| The first time the telephone is switched on, |
| • | all LEDs light up briefly |
| • | all LEDs on the add-on devices (AODs), if connected, light up briefly (AOD LEDs do not necessarily flash at the same time as the LEDs on the telephone) |
| • | all pixels on the display activate briefly. |
| These indications show that the telephone is starting up and performing a self-test. Downloading has finished and the telephone is ready for operation when you see the date and time on the display. |
10.5.1.8 |
Ports on the Bottom of the Telephone |
10.5.1.9 |
USB 1.1 Interface |
| With the exception of optiPoint 500 entry and optiPoint 500 economy, the optiPoint 500 telephones have a USB 1.1 interface. This forms the basis for: |
| • | PC-supported telephoning (TAPI) |
| • | Data transmission over CAPI (for example, direct Internet access, fax capability, e-mail, etc.). If the CAPI software is installed, PCs have direct Internet access over the USB interface without any additional adapter. There is a charge for this software. |
| TAPI and CAPI can be used simultaneously (for example, to receive a large e-mail or download data while calls are being set up over a CTI application). |
| HiPath 3000/5000 V8, Service Documentation, Issue 10 | up ![]() |
|
![]() |
||
| Disclaimer & Copyright | ID: P31003H3580S100017620 | 2011-01-24 |