D.2  

HiPath 3550 Board Power Requirement 
 

 Table D-3   Nominal Output of the HiPath 3550 Power Supply Units
 Power Supply Unit  
 Part Number  
 Max. Nominal Output in W  
 5 V  
 -48 V  
UPSC-D  
S30122-K5660-A300  
S30122-K5660-M300  
 40.0  
 53.0  
Powerbox PB3000 with LUNA2  
S30177-U773-X with S30122-K7686-M1  
 -  
 110  
You must check whether the total power requirement of the boards used and the workpoint clients connected exceeds the maximum possible output of the UPSC-D with or without Powerbox PB3000. Section D.7 "Checking Whether the Output of a Power Supply Unit is Sufficient" contains a sample calculation.  

 Table D-4   Board Power RequirementHiPath 3550
 Board or Component  
 Part Number  
 Net Power Requirement in W  
 5 V  
 -48 V  
BS3/1  
S30807-H5482-X  
 -  
 2.0  
BS3/3  
S30807-H5485-X  
 -  
 3.0  
CBCC (including subboards)  
S30810-Q2935-A301  
 7.0  
 0.5  
GEE12  
S30817-Q951-Axxx  
 0.5  
 -  
GEE16  
S30817-Q951-Axxx  
 0.5  
 -  
GEE50  
S30817-Q951-Axxx  
 0.5  
 -  
HXGS3 (including ventilator kit)  
S30810-Q2943-X  
 10.0  
 2.8  
HXGS3 (excluding ventilator kit)  
S30810-Q2943-X  
 10.0  
 -  
IVMS8  
S30122-Q7379-X  
 2.6  
 0.3  
PDM1  
S30807-Q5692-X100  
 -  
 5.0  
SLA8N  
S30810-Q2929-X200  
 0.2  
 0.5  
SLA16N  
S30810-Q2929-X100  
 3.0  
 3.0  
SLA24N  
S30810-Q2929-X  
 4.5  
 4.5  
SLAD4  
S30810-H2956-X100  
 2.0  
 1.0  
SLAD8  
S30810-H2956-X200  
 2.0  
 1.0  
SLAD16  
S30810-Q2957-X  
 2,5  
 1,51  
SLC16N  
S30810-Q2193-X100  
 5.0  
 -  
SLMO24  
S30810-Q2901-X  
 1.5  
 -  
SLU8  
S30817-Q922-A301  
 0.8  
 -  
STLS2  
S30817-Q924-B313  
 0.6  
 -  
STLS4  
S30817-Q924-A313  
 1.0  
 -  
STRB  
S30817-Q932-A  
 0.5  
 -  
TCAS-2  
S30810-Q2945-X  
 4.5  
 -  
TLA2  
S30817-Q923-Bxxx  
 0.1  
 -  
TLA4  
S30817-Q923-Axxx  
 0.2  
 -  
TLA8  
S30817-Q926-Axxx  
 0.4  
 -  
TMAMF  
S30810-Q2587-A400  
 1.82  
 16.92  
TMCAS  
S30810-Q2938-X  
   
TMGL4  
S30810-Q2918-X  
 4.72  
 0.12  
TMQ4  
S30810-Q2917-X  
 3.8  
 -  
TST1  
S30810-Q2919-X  
 0.8  
 -  
TS2  
S30810-Q2913-X300  
 0.9  
 -  
V24/1  
S30807-Q6916-X100  
 0.3  
 -  
4SLA  
S30810-Q2923-X200  
 0.7  
 0.7  
8SLA  
S30810-Q2923-X100  
 1.3  
 1.3  
16SLA  
S30810-Q2923-X  
 2.5  
 2.5  
1For each active station (off hook), the net resource requirement increases by approx. 1.6 W (dependant on the phone's cable length and DC resistance).
2Identified at a traffic flow of 0.8 Erlang