3.3.27  

STMD3 
 
NOTE: Danger of damage to property due to surge voltage. The required lightning protection measures must be taken for this board, see Section 2.1.2 "Lightning Protection".  

Introduction  
The STMD3 (Subscriber and Trunk Module Digital S0) board contains eight S0 basic rate accesses for HiPath 3800.
The range of the short S0 bus (up to eight Terminal Equipment Identifiers (TEI)) is limited to approximately 60 m.  
If longer cables are required, the S0 bus type must be set to "Long" in HiPath 3000/5000 Manager E developer mode. This provides a range of approximately 160 m. This setting can be made in V5.0 SMR-05 (CV 5) or later.  

Front panel  
 Figure 3-83   STMD3 (S30810-Q2217-X10) - LEDs in the Front Panel
 
To ensure sufficient shielding, provide the board with a shielding panel. For information on mounting the shielding panel, see Section 4.1.5.3 "Inserting or Removing Boards".  

LED statuses and their meanings  

 Table 3-110   STMD3 - LED Statuses
 Red LED  
 Green LED  
 Status  
 Action  
 Off  
 Off  
Board not receiving power or not plugged in correctly.  
Board is out of order.  
Check plug contact on board.  
 On  
 Off  
Board is receiving power and board test is in progress.  
Board is defective if status remains unchanged (board test unsuccessful).  
 
 
Replace the board.  
Loadware loading not successfully completed. Board is faulty.  
Replace the board.  
Error detected on board.  
Board is deactivated (not applicable to errors detected by test loops) or board was deactivated using HiPath 3000/5000 Manager E.  
Check whether the board was deactivated using HiPath 3000/5000 Manager E. If not, replace board.  
 Flashing  
 Off  
Loadware is being loaded.  
 
 Off  
 On  
Board test completed successfully. Board is OK (idle state).  
 
 Off  
 Flashing  
At least one channel is activated.  
 

Cable and connector assignment  
 •   For connecting to the SIVAPAC connector on the backplane: Table 3-111
 •   For connecting to the connector panels using RJ45 jacks: Table 3-112
 •   For U.S. only: For connecting to the connector panels with CHAMP jack: Table 3-113
 •   For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-114

 Table 3-111   STMD3 - SIVAPAC Connector Assignment on the Backplane
 Pair  
 a-wire1 (tip)  
 b-wire1 (ring)  
 SIVAPAC connector  
 STMD3  
 MDFU-E  
 Notes  
 1  
 wht/blu  
   
 1  
 1Ea  
 Basic
rate access 1
 
 1a  
   
   
 blu/wht  
 23  
 1Eb  
 1b  
 2  
 wht/ora  
   
 3  
 1Sa  
 2a  
   
   
 ora/wht  
 4  
 1Sb  
 2b  
 3  
 wht/grn  
   
 5  
 2Ea  
 Basic
rate access 2
 
 3a  
   
   
 grn/wht  
 6  
 2Eb  
 3b  
 4  
 wht/brn  
   
 7  
 2Sa  
 4a  
   
   
 brn/wht  
 8  
 2Sb  
 4b  
 5  
 wht/gry  
   
 9  
 3Ea  
 Basic
rate access 3
 
 5a  
   
   
 gry/wht  
 10  
 3Eb  
 5b  
 6  
 red/blu  
   
 11  
 3Sa  
 6a  
   
   
 blu/red  
 12  
 3Sb  
 6b  
 7  
 red/ora  
   
 13  
 4Ea  
 Basic
rate access 4
 
 7a  
   
   
 ora/red  
 14  
 4Eb  
 7b  
 8  
 red/grn  
   
 15  
 4Sa  
 8a  
   
   
 grn/red  
 16  
 4Sb  
 8b  
 9  
 red/brn  
   
 17  
 5Ea  
 Basic
rate access 5
 
 9a  
   
   
 brn/red  
 18  
 5Eb  
 9b  
 10  
 red/gry  
   
 19  
 5Sa  
 10a  
   
   
 gry/red  
 20  
 5Sb  
 10b  
 11  
 blk/blu  
   
 24  
 6Ea  
 Basic
rate access 6
 
 11a  
   
   
 blu/blk  
 25  
 6Eb  
 11b  
 12  
 blk/ora  
   
 26  
 6Sa  
 12a  
   
   
 ora/blk  
 27  
 6Sb  
 12b  
 13  
 blk/grn  
   
 29  
 7Ea  
 Basic
rate access 7
 
 13a  
   
   
 grn/blk  
 30  
 7Eb  
 13b  
 14  
 blk/brn  
   
 31  
 7Sa  
 14a  
   
   
 brn/blk  
 32  
 7Sb  
 14b  
 15  
 blk/gry  
   
 34  
 8Ea  
 Basic
rate access 8
 
 15a  
   
   
 gry/blk  
 35  
 8Eb  
 15b  
 16  
 yel/blu  
   
 37  
 8Sa  
 16a  
   
   
 blu/yel  
 38  
 8Sb  
 16b  
1see "Abbreviations for colors" at the start of Section 3.3 "Peripheral Boards".

 Table 3-112   STMD3 - Connector Panel Assignment with RJ45 Jacks
 RJ45 jack  
 STMD3  
 Notes  
 No.  
 Subscriber line  
 Pin  
 Trunk connection  
 Pin  
 1  
 3  
 4  
 1Ea  
 Basic
rate access 1
 
   
 6  
 5  
 1Eb  
 4  
 3  
 1Sa  
   
 5  
 6  
 1Sb  
 2  
 3  
 4  
 2Ea  
 Basic
rate access 2
 
   
 6  
 5  
 2Eb  
 4  
 3  
 2Sa  
   
 5  
 6  
 2Sb  
 3  
 3  
 4  
 3Ea  
 Basic
rate access 3
 
   
 6  
 5  
 3Eb  
 4  
 3  
 3Sa  
   
 5  
 6  
 3Sb  
 4  
 3  
 4  
 4Ea  
 Basic
rate access 4
 
   
 6  
 5  
 4Eb  
 4  
 3  
 4Sa  
   
 5  
 6  
 4Sb  
 5  
 3  
 4  
 5Ea  
 Basic
rate access 5
 
   
 6  
 5  
 5Eb  
 4  
 3  
 5Sa  
   
 5  
 6  
 5Sb  
 6  
 3  
 4  
 6Ea  
 Basic
rate access 6
 
   
 6  
 5  
 6Eb  
 4  
 3  
 6Sa  
   
 5  
 6  
 6Sb  
 7  
 3  
 4  
 7Ea  
 Basic
rate access 7
 
   
 6  
 5  
 7Eb  
 4  
 3  
 7Sa  
   
 5  
 6  
 7Sb  
 8  
 3  
 4  
 8Ea  
 Basic
rate access 8
 
   
 6  
 5  
 8Eb  
 4  
 3  
 8Sa  
   
 5  
 6  
 8Sb  

 Table 3-113   STMD3 - Connector Panel Assignment with CHAMP Jack (for U.S. only)
 CHAMP jack  
 STMD3  
 Notes  
 1  
 S0, Receive  
 Basic
rate access 1
 
   
 26  
 S0, Receive  
 2  
 S0, Transmit  
   
 27  
 S0, Transmit  
 3  
 S0, Receive  
 Basic
rate access 2
 
   
 28  
 S0, Receive  
 4  
 S0, Transmit  
   
 29  
 S0, Transmit  
 5  
 S0, Receive  
 Basic
rate access 3
 
   
 30  
 S0, Receive  
 6  
 S0, Transmit  
   
 31  
 S0, Transmit  
 7  
 S0, Receive  
 Basic
rate access 4
 
   
 32  
 S0, Receive  
 8  
 S0, Transmit  
   
 33  
 S0, Transmit  
 9  
 S0, Receive  
 Basic
rate access 5
 
   
 34  
 S0, Receive  
 10  
 S0, Transmit  
   
 35  
 S0, Transmit  
 11  
 S0, Receive  
 Basic
rate access 6
 
   
 36  
 S0, Receive  
 12  
 S0, Transmit  
   
 37  
 S0, Transmit  
 13  
 S0, Receive  
 Basic
rate access 7
 
   
 38  
 S0, Receive  
 14  
 S0, Transmit  
   
 39  
 S0, Transmit  
 15  
 S0, Receive  
 Basic
rate access 8
 
   
 40  
 S0, Receive  
 16  
 S0, Transmit  
   
 41  
 S0, Transmit  

 Table 3-114   STMD3 - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for Ports 1 - 16)
 Color
group
 
 Pair  
 a-wire1 (tip)  
 b-wire1 (ring)  
 SU
connector
 
 STMD3  
 MDFU-E  
 S0 patch panel,
MW8 pin
 
 Subscriber
line
 
 Trunk
connection
 
 1  
 1  
 wht/blu  
   
 19  
 1Ea  
 Basic
rate access 1
 
 1a  
 3  
 4  
   
 blu/wht  
 39  
 1Eb  
 1b  
 6  
 5  
 2  
 wht/ora  
   
 38  
 1Sa  
 2a  
 4  
 3  
   
 ora/wht  
 48  
 1Sb  
 2b  
 5  
 6  
 3  
 wht/grn  
   
 27  
 2Ea  
 Basic
rate access 2
 
 3a  
 3  
 4  
   
 grn/wht  
 47  
 2Eb  
 3b  
 6  
 5  
 4  
 wht/brn  
   
 16  
 2Sa  
 4a  
 4  
 3  
   
 brn/wht  
 46  
 2Sb  
 4b  
 5  
 6  
 5  
 wht/gry  
   
 05  
 3Ea  
 Basic
rate access 3
 
 5a  
 3  
 4  
   
 gry/wht  
 45  
 3Eb  
 5b  
 6  
 5  
 2  
 6  
 red/blu  
   
 14  
 3Sa  
 6a  
 4  
 3  
   
 blu/red  
 44  
 3Sb  
 6b  
 5  
 6  
 7  
 red/ora  
   
 23  
 4Ea  
 Basic
rate access 4
 
 7a  
 3  
 4  
   
 ora/red  
 43  
 4Eb  
 7b  
 6  
 5  
 8  
 red/grn  
   
 32  
 4Sa  
 8a  
 4  
 3  
   
 grn/red  
 42  
 4Sb  
 8b  
 5  
 6  
 9  
 red/brn  
   
 11  
 5Ea  
 Basic
rate access 5
 
 9a  
 3  
 4  
   
 brn/red  
 31  
 5Eb  
 9b  
 6  
 5  
 10  
 red/gry  
   
 02  
 5Sa  
 10a  
 4  
 3  
   
 gry/red  
 22  
 5Sb  
 10b  
 5  
 6  
 3  
 11  
 blk/blu  
   
 13  
 6Ea  
 Basic
rate access 6
 
 11a  
 3  
 4  
   
 blu/blk  
 33  
 6Eb  
 11b  
 6  
 5  
 12  
 blk/ora  
   
 04  
 6Sa  
 12a  
 4  
 3  
   
 ora/blk  
 24  
 6Sb  
 12b  
 5  
 6  
 13  
 blk/grn  
   
 15  
 7Ea  
 Basic
rate access 7
 
 13a  
 3  
 4  
   
 grn/blk  
 35  
 7Eb  
 13b  
 6  
 5  
 14  
 blk/brn  
   
 06  
 7Sa  
 14a  
 4  
 3  
   
 brn/blk  
 26  
 7Sb  
 14b  
 5  
 6  
 15  
 blk/gry  
   
 17  
 8Ea  
 Basic
rate access 8
 
 15a  
 3  
 4  
   
 gry/blk  
 37  
 8Eb  
 15b  
 6  
 5  
 4  
 16  
 yel/blu  
   
 08  
 8Sa  
 16a  
 4  
 3  
   
 blu/yel  
 28  
 8Sb  
 16b  
 5  
 6  
1see "Abbreviations for colors" at the start of Section 3.3 "Peripheral Boards".