3.3.12  

SLAD4, SLAD8, SLAD8R 
 
NOTE: Danger of damage to property due to surge voltage. The required lightning protection measures must be taken for this board, see Section 2.1.2 "Lightning Protection".  

Introduction  
In HiPath 3000/5000 V6 R4 and V7 R4 and later, the following boards can be used to connect analog subscribers (analog phones, group 3 fax, etc.):
 •   SLAD4 (Subscriber Line Analog with DuSLIC) S30810-H2956-X100 - for HiPath 3550 and HiPath 3350
 •   SLAD8 (Subscriber Line Analog with DuSLIC) S30810-H2956-X200 - for HiPath 3550 and HiPath 3350
 •   SLAD8R (Subscriber Line Analog with DuSLIC Rack) S30810-K2956-X300 - for
HiPath 3500 and HiPath 3300
The SLAD boards are compatible successor modules for the following boards:
 •   4SLA (S30810-Q2923-X200)
 •   8SLA (S30810-Q2923-X100)
 •   8SLAR (S30810-K2925-Z).
These are being phased out and can no longer be ordered.

Main features  
A DTMF code receiver is available for each analog interface (permits DTMF dialing at analog telephones. This guarantees that all analog terminals connected are fully accessible.
These boards support calling name identification presentation (CLIP).
The connection of external extensions via OPS (Off-Premises Station) signaling is supported.
Ring voltage is generated by the power supply unit of the relevant system (UPSC-D for SLAD4 and SLAD8, UPSC-DR for SLAD8R). Information about country-specific ring frequency settings is provided in Section 2.8 "Country-Specific Ring Frequencies for Analog Subscriber Line Modules".

SLAD4, SLAD8 interfaces  
 Figure 3-54   SLAD4, SLAD8 - interfaces
 

 Table 3-59   SLAD4, SLAD8 - assigning the ports
 X2, Pin  
 T/R ports 1-4  
 X3, Pin  
 T/R ports 5-8  
 1  
 a 1  
 1  
 a 5  
 2  
 b 1  
 2  
 b 5  
 3  
 a 2  
 3  
 a 6  
 4  
 b 2  
 4  
 b 6  
 5  
 a 3  
 5  
 a 7  
 6  
 b 3  
 6  
 b 7  
 7  
 a 4  
 7  
 a 8  
 8  
 b 4  
 8  
 b 8  
Nur für USA:  
Bei SLAD4 und SLAD8 sind außenliegende Nebenstellen an den a/b-Ports über OPS-Signalisierung (im Folgenden: OPS-Ports) anschließbar. Die Anzahl der OPS-Ports ist begrenzt. Folgende Maximalzahlen dürfen nicht überschritten werden:  
 •   in HiPath 33x0: max. 4 OPS-Ports
 •   in HiPath 35x0: max. 8 OPS-Ports und max. 4 OPS-Ports pro Baugruppe
An SLAD16 sind OPS-Ports generell verboten.  

SLAD8R interfaces  
 Figure 3-55   SLAD8R - interfaces
 

 Table 3-60   SLAD8R - assigning the ports
 RJ45 jack  
 X2, Pin  
 T/R ports 1-4  
 RJ45 jack  
 X2, Pin  
 T/R ports 5-8  
 1  
 14  
 a 1  
 5  
 54  
 a 5  
 15  
 b 1  
 55  
 b 5  
 2  
 24  
 a 2  
 6  
 64  
 a 6  
 25  
 b 2  
 65  
 b 6  
 3  
 34  
 a 3  
 7  
 74  
 a 7  
 35  
 b 3  
 75  
 b 7  
 4  
 44  
 a 4  
 8  
 84  
 a 8  
 45  
 b 4  
 85  
 b 8