3.3.10  

PBXXX (for selected countries only) 
 

Introduction  
The PBXXX (Peripheral Board XXX) module can be used in HiPath 3800 to support country-specific CAS protocols.
The peripheral board slots on the HiPath 3800 are fitted with SIPAC 9 SU connectors. Since the PBXXX board has SIVAPAC connector strips, you will have to install a SIVAPAC-SIPAC board adapter to be able to use it in HiPath 3800.  
For information on this procedure, please see Section 4.1.5.5 "Installing the SIVAPAC-SIPAC Board Adapter".  
The PBXXX board converts the Euro-ISDN protocol on an S2M link into the Channel Associated Signaling (CAS) protocol. The board functions only in conjunction with a DIUN2. There is no direct connection between the PBXXX board and the system's central control unit. The DIUN2 handles all signaling and data traffic.
The following combination options are possible:
 •   1 x DIUN2 + 1 x PBXXX (see Page 3-129)
The PBXXX board must be plugged in on the left next to the DIUN2.
 •   1 x DIUN2 + 2 x PBXXX (see Page 3-132)
The PBXXX boards must be plugged in on the left and right next to the DIUN2.
Up to four PBXXX boards can be installed in a HiPath 3800. For power supply reasons, a maximum of two PBXXX can be installed in a cabinet.

Administration of the CAS protocol converter  
Use the ECGM tool for administration. For information on installing the software on the service PC and on the required settings, see Page 3-303.
The C39195-Z7267-C2 cable can be used with a C39334-Z7080-C2 adapter (9-pin Sub-D jack - 25-pin Sub-D jack) to connect the PBXXX (port M) and the service PC.

Notes on setup using HiPath 3000/5000 Manager E  
Because the PBXXX card is not recognized by the hardware, offline configuration is required with HiPath 3000/5000 Manager E. Either "DIUN2 + PBXXX" or "DIUN2 + 2PBXXX" should be specified as the board to be configured. After configuration, the module data can be seen in HiPath 3000/5000 Manager E. However, this is only visible in the software configuration, as the PBXXX card was only configured on the software side.
Note: The offline configuration of the PBXXX serves solely to visualize the card with
HiPath 3000/5000 Manager E.

Front panel  
 Figure 3-47   PBXXX (S30810-Q6401-X) (for selected countries) - Front Panel
 

Seven-segment display  
The board statuses listed in the following table are displayed.

 Table 3-52   PBXXX (for selected countries only) - Seven-Segment Display
 Display  
 Meaning  
 
Waiting for the PBXXX software download  
 
Starting the PBXXX software download  
 
PBXXX software download  
 
Writing the PBXXX software/extender software to the flash memory  
 
Loading the PBXXX software/extender software from the flash memory  
 
Waiting for ECGM command (10 s)  
 
Error while writing the software to flash memory  
 
No software in the flash memory, waiting for reload  
 
Flash memory erased (changing display)  
 
PBXXX card active, Link 1 and Link 2 not active  
 
Link 1 active, Link 2 not active  
 
Link 1 not active, Link 2 active  
 
Link 1 active, Link 2 active  
 
Boot procedure  

Connection 1x DIUN2 + 1 x PBXXX  
The figure below shows an example of a DIUN2 with one PBXXX in the basic cabinet.
 Figure 3-48   HiPath 3800 Basic Cabinet - 1x DIUN2 + 1 x PBXXX
 
 Figure 3-49   PBXXX (for selected countries only) - Connecting the CAS Cable using the APPCU Adapter
 
The backplane of the PBXXX board must be closed with the adapter panels provided (C39165-A7050-C35, Figure 3-50).  
 Figure 3-50   PBXXX (for selected countries only) - Adapter Panel (C39165-A7050-C35)
 

Connection 1x DIUN2 + 2 x PBXXX  
The figure below shows an example of a DIUN2 with two PBXXXs in the basic cabinet.
 Figure 3-51   HiPath 3800 Basic Cabinet - 1x DIUN2 + 2 x PBXXX
 
 Figure 3-52   PBXXX (for selected countries only) - Connecting the CAS Cable using Two APPCU Adapters
 
The backplane of both PBXXX boards must be closed with the adapter panels provided (C39165-A7050-C35, Figure 3-50).  

Assigning both CAS cables  
The following CAS cables are connected to the backplane via two APPCU adapters:
 •   symmetrical line (120 ohms), open end
   
 Table 3-53   Assigning the CAS cable S30267-Z167-A100
 15-pin Sub-D connector  
 Pin  
 Function  
 Color code  
 9  
 a-wire (T), transmit  
 wht/blu  
 1  
 b-wire (R), transmit  
 blu/wht  
 15  
 a-wire (T), receive  
 wht/ora  
 8  
 b-wire (R), receive  
 ora/wht  
 •   coaxial line (75 ohms)
   
 Table 3-54   Assigning the CAS cable S30267-Z80-A100
 15-pin Sub-D connector  
 Pin  
 Function  
 Wire  
 15  
 a-wire (T), receive  
 BNC line, cable 1  
 8  
 b-wire (R), receive  
 BNC shield, cable 1  
 9  
 a-wire (T), transmit  
 BNC line, cable 2  
 1  
 b-wire (R), transmit  
 BNC shield, cable 2